Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G & G HOME IMPROVEMENTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G & G HOME IMPROVEMENTS in 1663 KRAMER STREET NE, WASHINGTON, DC 20001 (NAICS 238160). OSHA activity number 346368905.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G & G Home Improvements — free Get an email when a new federal OSHA severe-injury report for G & G Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
1663 KRAMER STREET NE
City
WASHINGTON
State
DC
ZIP
20001
Mailing
455 MASSACHUSETTS AVENUE NORTHWEST STE 304, WASHINGTON, DC 20001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 8, 2023
Abate by
Mar 16, 2023
Penalty
Initial $4,688 · Current $3,281 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about November 29, 2022,  Northeast Side;  Employees were installing trim and flashing on a residential home approximately 25 to 30-feet above the ground without any means of fall protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3281
  • — Z (S) $4688

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346368905.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.