ROXANA, IL —
OSHA Inspection: STERETT CRANE AND RIGGING LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of STERETT CRANE AND RIGGING LLC in 900 S. CENTRAL AVE, ROXANA, IL 62084 (NAICS 532412). OSHA activity number 346378474.
Where did this inspection happen?
- Establishment
- STERETT CRANE AND RIGGING LLC
- Site address
- 900 S. CENTRAL AVE
- City
- ROXANA
- State
- IL
- ZIP
- 62084
- Mailing
- 34 BOOTH FIELD RD., OWENSBORO, KY 42301
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532412
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1404 M01 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15625.00
General-duty citation text
29 CFR 1926.1404(m)(1)(i): The selection of components, and configuration of the equipment, that affect the capacity or safe operation of the equipment was not in accordance with manufacturer instructions, prohibitions, limitations, and specifications: On or about December 6, 2022, a Terex CC2800-1, 660-Ton Crawler Mounted Lattice Boom Crane, was used at Phillips 66 Wood River Refinery to place a Kerosene Hydrotreater Reactor. The crane components and configuration were not in accordance with manufacturer specifications. Capacity and safe operation of the equipment was affected. a. The SuperLift counterweight frame was not connected to the SuperLift support rods with manufacturer specified rods. b. The SuperLift counterweight frame was not connected to the crane superstructure with manufacturer specified connecting ropes.
Recent events (2)
- — I (S) $15625
- — Z (S) $15625
1926.1404 M02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1404(m)(2): Upon completion of assembly, the equipment was not inspected to ensure compliance with paragraph (m)(1) of this section (see � 1926.1412(c) for post-assembly inspection requirements): On or about December 6, 2022, a Terex CC2800-1, 660-Ton Crawler Mounted Lattice Boom Crane, was used at Phillips 66 Wood River Refinery to place a Kerosene Hydrotreater Reactor. The SuperLift components and configuration were not inspected upon completion of assembly to ensure compliance with manufacturer specifications.
Recent events (2)
- — I (S) $0
- — Z (S) $15625
1904.40 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. On or about December 14, 2022, the year-to-date OSHA Form 300 for the year 2022 was requested by an authorized OSHA representative and the document was not provided within four business hours or on the date provided in the written request.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 532412)
DURHAM, NC—2026-07-08
161503 - SUNBELT RENTALS, INC.
SUNNYVALE, CA—2026-06-11
SUNBELT RENTALS
SOPHIA, WV—2026-06-03
BOYD COMPANY
CRESTWOOD, KY—2026-06-03
69172 - SKYWORKS LLC
WINTERSVILLE, OH—2026-05-20
MURPHY FAMILY INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346378474.