Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INOTIV INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INOTIV INC. in 1401 S. STOUGHTON RD., MADISON, WI 53716 (NAICS 541990). OSHA activity number 346378615.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inotiv INC. — free Get an email when a new federal OSHA severe-injury report for Inotiv INC. is published. One employer, no account, unsubscribe in one click.
Establishment
INOTIV INC.
Site address
1401 S. STOUGHTON RD.
City
MADISON
State
WI
ZIP
53716
Mailing
8520 ALLISON PT BLVD, INDIANAPOLIS, IN 46250
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541990
Employees
36
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 28, 2023
Abate by
Apr 5, 2023
Penalty
Initial $15,625 · Current $9,375 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  On or about November 28, 2022 procedures were not utilized for the control of potentially hazardous energy when employee's were engaged in cleaning the Pellet Mill Conditioner.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625

1910.147 C04 II D

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 28, 2023
Abate by
Apr 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(D):The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control.  On or about November 28, 2022 energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices when employee's were engaged in cleaning the Pellet Mill Conditioner.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 28, 2023
Abate by
Apr 5, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  On or about November 28, 2022, an employee was not required to apply the established energy control procedure in sequence, nor did the procedures cover relieving all potentially hazardous stored or residual energy when cleaning the Pellet Mill Conditioner.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from the unexpected energization, startup, or release of stored energy during machine servicing and maintenance activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 28, 2023
Abate by
Apr 5, 2023
Penalty
Initial $11,162 · Current $6,697 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about November 28, 2022, the employer had not conducted a periodic inspection of the energy control procedure for the Pellet Mill/Conditioner at least annually to ensure that the procedure and the requirement of this standard were being followed.
Recent events (2)
  • — I (S) $6697.2
  • — Z (S) $11162

View Inotiv INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346378615.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.