HUDSON, WI —
OSHA Inspection: HERMS CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HERMS CONSTRUCTION in 861 HARTMAN CIRCLE, HUDSON, WI 54016 (NAICS 238130). OSHA activity number 346381809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HERMS CONSTRUCTION
- Site address
- 861 HARTMAN CIRCLE
- City
- HUDSON
- State
- WI
- ZIP
- 54016
- Mailing
- 2817 POLK-ST. CROIX ROAD, CLEAR LAKE, WI 54005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.453 B02 IV
- Issued
- Dec 23, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(iv): Employee(s) were not standing firmly on the floor of the basket, were sitting or climbing on the edge of the basket, or were using planks, ladders, or other devices for a work position: (a) North side of commercial building; A worker using a Genie model S-45 extensible boom lift, serial no. S4506-11032, to egress the roof was standing outside of the basket while holding onto the guardrail as the basket was lowered from an approximate height of 17-feet above ground level.
Recent events (3)
- — F (S) $0
- — C (S) $4351
- — Z (S) $4351
1926.453 B02 V
- Issued
- Dec 23, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) Commercial building, various locations; Workers used a Genie model S-45 extensible boom lift, serial no. S4506-11032, to access and egress the roof and/or perform framing work at an approximate height of 17-feet above ground level without the use of personal fall protection.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.453 B02 VI
- Issued
- Dec 23, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $1,865 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(vi): Boom and basket load limits specified by the manufacturer were exceeded: (a) Commercial building, various locations; A Genie model S-45, serial no. S4506-11032 extensible boom lift was used in excess of the occupant/load capacity of two persons/500 lbs. as three workers occupied the basket while using the lift to access and/or egress the roof.
Recent events (3)
- — F (S) $0
- — C (S) $1865
- — Z (S) $1865
1926.501 B10
- Issued
- Dec 23, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Commercial roof structure, various locations; Workers installing steel roof panels from a low-slope roof were not protected from falls while working at approximate heights ranging between 17-feet to 29-feet, 3-inches above ground level.
Recent events (3)
- — F (S) $0
- — C (S) $4351
- — Z (S) $4351
1926.503 A01
- Issued
- Dec 23, 2022
- Abate by
- Jan 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Commercial roof structure, various locations; Workers exposed to fall hazards at heights ranging between approximately 17-feet to 29-feet, 3-inches above ground level were not trained on fall hazard recognition and mitigation methods.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346381809.