OSHA Inspection: UTILITY TRAILER MANUFACTURING COMPANY

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of UTILITY TRAILER MANUFACTURING COMPANY in 2921 HWY 49 N, PARAGOULD, AR 72450 (NAICS 336212). OSHA activity number 346383714.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utility Trailer Manufacturing Company — free Get an email when a new federal OSHA severe-injury report for Utility Trailer Manufacturing Company is published. One employer, no account, unsubscribe in one click.
Site address
2921 HWY 49 N
City
PARAGOULD
State
AR
ZIP
72450
Mailing
P.O. BOX 1606, PARAGOULD, AR 72450
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
900
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 9, 2023
Abate by
Feb 21, 2025
Penalty
Initial $15,625 · Current $16,131
OSH ACT of 1970 Section (5)(a)(1)  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards.  (a) On or about December 10, 2022, the employer did not provide specific written instructions and communicate hazards to employees performing service and maintenance on a Southworth Scissor-Lift Table. One feasible and acceptable means of abatement would be to adequately label and communicate all applicable energy sources for the Southworth Scissor-Lift table to employees.
Recent events (3)
  • — F (S) $16131
  • — C (S) $15625
  • — Z (S) $15625

1910.147 C04 II B

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jun 9, 2023
Abate by
Jun 29, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   a) On or about December 10, 2022, at the axle line, employees were performing servicing and maintenance activities on the lift table comprised of components including, but not limited to a roller conveyor and Southworth LS lift table; and the energy control procedure did not have outlined steps for isolating all sources of hazardous energy.
Recent events (3)
  • — F (S) $0
  • — C (S) $11162
  • — Z (S) $11162

1910.147 C04 II C

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jun 9, 2023
Abate by
Jun 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(C):  The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:   a) On or about December 10, 2022 , at the axle line, employees were performing servicing and maintenance activities on the lift table comprised of components including, but not limited to a roller conveyor and Southworth LS lift table; and the energy control procedures did not have procedures for affixing and removing locks on the electrical energy sources.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 II D

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jun 9, 2023
Abate by
Jun 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(D):  The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures:   a) On or about December 10, 2022, at the axle line, employees were performing servicing and maintenance activities on the lift table comprised of components including, but not limited to a roller conveyor and Southworth LS lift table with energy sources such as, but not limited to hydraulic, electrical, and mechanical.  The procedures did not include specific steps to verify the effectiveness of the energy control measures.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C05 I

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Jun 9, 2023
Abate by
Jun 22, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:   (a) On or about December 10, 2022, employees were performing servicing and maintenance on a lift table comprised of a roller conveyor and LS Series lift table by Southworth.  Hardware was not provided to secure and/or block the upper portion of the lift table loaded with the roller conveyor.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

View Utility Trailer Manufacturing Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346383714.