LISBON FALLS, ME —
OSHA Inspection: MAINE RECYCLING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAINE RECYCLING CORPORATION in 61 CAPITAL AVENUE, LISBON FALLS, ME 04252 (NAICS 562920). OSHA activity number 346383946.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAINE RECYCLING CORPORATION
- Site address
- 61 CAPITAL AVENUE
- City
- LISBON FALLS
- State
- ME
- ZIP
- 04252
- Mailing
- 61 CAPITAL AVENUE, LISBON FALLS, ME 04252
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 67
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 D03
- Issued
- Mar 8, 2023
- Abate by
- May 24, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: Establishment: The employer did not require the use of energy isolating procedures when clearing jams in the automatic tying portion of the Balemaster baler identified as Baler #1.
Recent events (2)
- — I (S) $6562.8
- — Z (S) $10938
1910.147 C06 I
- Issued
- Mar 8, 2023
- Abate by
- May 24, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. Establishment: The employer did not inspect the energy control procedures of each machine annually to ensure requirements of the standard were being followed on equipment such as but not limited to the Balemaster 1, Balemaster 2, Enterprise 4, Enterprise 5, Excel 6, Glass Crusher Bud line, Load King 22, Main Pump Bud Line, Philadelphia 33, Philadelphia 44, Philadelphia 55, Philadelphia 66, and Selco 77.
Recent events (2)
- — I (S) $6562.8
- — Z (S) $10938
1910.147 C06 II
- Issued
- Mar 8, 2023
- Abate by
- May 24, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection. Establishment: The employer did not provide certification that the energy control procedures of each machine was conducted annually to ensure requirements of the standard were being followed on equipment such as but not limited to the Balemaster 1, Balemaster 2, Enterprise 4, Enterprise 5, Excel 6, Glass Crusher Bud line, Load King 22, Main Pump Bud Line, Philadelphia 33, Philadelphia 44, Philadelphia 55, Philadelphia 66, and Selco 77. Procedures provided were not signed, did not have the review date, and did not include an employee participation field.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Mar 8, 2023
- Abate by
- May 24, 2023
- Penalty
- Initial $10,938 · Current $6,563 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees. Establishment: The employer did not train affected and authorized employees on the purpose, function, and specific procedures of the energy control program.
Recent events (2)
- — I (S) $6562.8
- — Z (S) $10938
1910.178 L04 III
- Issued
- Mar 8, 2023
- Abate by
- Apr 12, 2023
- Penalty
- Initial $7,813 · Current $4,688 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Establishment: The employer did not ensure forklift and powered pallet jack operators were reevaluated at least once every three years.
Recent events (2)
- — I (S) $4687.8
- — Z (S) $7813
More inspections at Maine Recycling Corporation
View Maine Recycling Corporation's full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in ME