OSHA Inspection: OCEAN ORGANICS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OCEAN ORGANICS CORPORATION in 141 1 PIE ROAD, WALDOBORO, ME 04572 (NAICS 325314). OSHA activity number 346392798.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ocean Organics Corporation — free Get an email when a new federal OSHA severe-injury report for Ocean Organics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
141 1 PIE ROAD
City
WALDOBORO
State
ME
ZIP
04572
Mailing
141 1 PIE ROAD, WALDOBORO, ME 04572
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325314
Employees
18
Ownership type
A

8 citations on file for this inspection.

1910.157 C04

Serious Gravity 5 1 instance 18 exposed
Issued
Feb 27, 2023
Penalty
Initial $3,795 · Current $1,898 Reduced
29 CFR  1910.157(c)(4):  Portable fire extinguishers were not kept in their designated places at all times except during use:  Loading Ramp Entrance, Iron Beam - A fire extinguisher was not mounted in close proximity to the posted sign and bracket.
Recent events (2)
  • — I (S) $1897.5
  • — Z (S) $3795

1910.157 E02

Serious Gravity 5 3 instances 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 7, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  The employer did not conduct monthly checks on fire extinguishers, in the following instances:  a)  Production room extinguisher. b)  Warehouse extinguisher. c)  Maintenance shop extinguisher.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 27, 2023
Abate by
Mar 16, 2023
Penalty
Initial $3,795 · Current $1,898 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Bottling Machine - Lockout procedures were not developed for the bottling machine.
Recent events (2)
  • — I (S) $1897.5
  • — Z (S) $3795

1910.178 L04 III

Serious Gravity 5 4 instances 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 6, 2023
Penalty
Initial $3,795 · Current $1,898 Reduced
29 CFR  1910.178(l)(4)(iii):  An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.  Establishment - An evaluation of powered industrial truck operator performance was not conducted at least once every three years.
Recent events (2)
  • — I (S) $1897.5
  • — Z (S) $3795

1910.219 C04 I

Serious Gravity 1 1 instance 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 7, 2023
Penalty
Initial $2,277 · Current $1,139 Reduced
29 CFR  1910.219(c)(4)(i):  Unguarded projecting shaft end(s) did not present a smooth edge and end and/or projected more than one-half the diameter of the shaft:  Production Room - Projecting shaft end was not guarded.
Recent events (2)
  • — I (S) $1138.5
  • — Z (S) $2277

1910.303 B01

Serious Gravity 1 1 instance 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 16, 2023
Penalty
Initial $2,277 · Current $1,139 Reduced
29 CFR  1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):  Interior Wall Between "PIT" and Production Room - The electrical panel was contaminated with dust and cobwebs.
Recent events (2)
  • — I (S) $1138.5
  • — Z (S) $2277

1910.303 F02

Serious Gravity 1 1 instance 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 16, 2023
Penalty
Initial $2,277 · Current $1,139 Reduced
29 CFR  1910.303(f)(2):  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device was not legibly marked to indicate its purpose:  Interior Wall Between "PIT" and Production Room - Only 3 of the 13 overcurrent devices were labeled in the electrical panel.
Recent events (2)
  • — I (S) $1138.5
  • — Z (S) $2277

1910.303 G02 I

Serious Gravity 10 1 instance 18 exposed
Issued
Feb 27, 2023
Abate by
Mar 16, 2023
Penalty
Initial $5,313 · Current $2,657 Reduced
29 CFR  1910.303(g)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  Interior Wall Between "PIT" and Production Room - Electrical panel did not have a dead front or enclosure to protect employees from coming into contact with live parts.
Recent events (2)
  • — I (S) $2656.5
  • — Z (S) $5313

View Ocean Organics Corporation's full OSHA safety record →