EAU CLAIRE, WI —
OSHA Inspection: PHILLIPS-MEDISIZE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PHILLIPS-MEDISIZE, LLC in 2930 MONDOVI ROAD, EAU CLAIRE, WI 54701 (NAICS 339112). OSHA activity number 346393069.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PHILLIPS-MEDISIZE, LLC
- Site address
- 2930 MONDOVI ROAD
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 2930 MONDOVI ROAD, EAU CLAIRE, WI 54701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 D04 I
- Issued
- Apr 6, 2023
- Abate by
- Apr 27, 2023
- Penalty
- Initial $6,831 · Current $4,782 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Injection molding department, press JSW-1; An employee performed service and maintenance tasks involving the replacement of a heater band contactor on a Japan Steel Works model JLM245-MG Injection Molding Machine without affixing lockout or tagout device(s) to the equipment's electrical energy source(s).
Recent events (2)
- — I (S) $4781.7
- — Z (S) $6831
1910.303 B07 I
- Issued
- Apr 6, 2023
- Abate by
- Apr 27, 2023
- Penalty
- Initial $5,122 · Current $3,585 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: (a) Injection molding department, near press JSW-2; A 4-outlet electrical box used to supply power to equipment located at the flex arm workstation was missing a knockout plug, exposing live inner conductors.
Recent events (2)
- — I (S) $3585.4
- — Z (S) $5122
1910.305 G01 IV A
- Issued
- Apr 6, 2023
- Abate by
- Apr 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Injection molding department, near press JSW-2; A corded, portable 4-outlet electrical box, plugged-into a fixed outlet was connected to another 4-outlet electrical box which was used to supply power to equipment located at the flex arm workstation. (b) Injection molding department, near the Husky #5 press; A relocatable power tap, connected by means of a corded, portable 4-outlet electrical box to an overhead fixed outlet, was used to supply power to equipment located near the quality control workstation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Phillips-Medisize, LLC
View Phillips-Medisize, LLC's full OSHA safety record →
More inspections in this industry (NAICS 339112)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346393069.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.