OSHA Inspection: TULALIP RESORT CASINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TULALIP RESORT CASINO in 10200 QUIL CEDA BLVD., TULALIP, WA 98271 (NAICS 721120). OSHA activity number 346397458.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tulalip Resort Casino — free Get an email when a new federal OSHA severe-injury report for Tulalip Resort Casino is published. One employer, no account, unsubscribe in one click.
Site address
10200 QUIL CEDA BLVD.
City
TULALIP
State
WA
ZIP
98271
Mailing
10200 QUIL CEDA BLVD., TULALIP, WA 98271
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
600
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $6,831 · Current $4,782 Reduced
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   a) Warehouse HVAC maintenance room, a compressed gas cylinder containing Nitrogen was adjacent to the wall and not properly secured for storage, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $4781.7
  • — Z (S) $6831

1910.178 G02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $6,831 · Current $0 Reduced
29 CFR  1910.178(g)(2): Facilities were not provided with adequate ventilation for dispersal of fumes from gassing batteries.  (a)  In the facility's main warehouse the employer had a charging area for the electric fork lifts that used lead/acid batteries. Accumulation of Hydrogen and Oxygen gasses can lead to fires and explosions exposing employees to burns and smoke inhalation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6831

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $5,122 · Current $3,585 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   (a)  In the facility's food/beverage shipping and receiving loading dock area a 120 Volt Electrical Panel Box (XLALD) was blocked by a stationary storage shelf, clutter, and cleaning materials that would restrict employee access to the panel in an emergency.
Recent events (2)
  • — I (S) $3585.4
  • — Z (S) $5122

1910.303 B02

Other-than-serious Gravity 1 1 instance 50 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $5,122 · Current $2,561 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   (a)  In the Blackfish Grill Kitchen, the employer utilized a pendant cord power supply equipped with a receptacle enclosed in a standard fixture box to power an Alto-Shaam Food warmer cabinet on wheels. The fixture box was not sufficiently durable to be used as part of a pendant box.
Recent events (2)
  • — I (O) $2561
  • — Z (S) $5122

1910.37 A03

Other-than-serious 1 instance 50 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit route was not kept free and unobstructed:  a)  In the Employee Dining Room Kitchen, kitchen push-carts were located within the exit pathway and obstructed the area's labeled emergency exit route.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 7 exposed
Issued
Mar 13, 2023
Abate by
Apr 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted so that they were readily accessible without subjecting the employees to possible injuries:  (a)      On the floor next to the access door connecting the Blackfish Grill prep area and kitchen, there was a fire extinguisher that was not mounted and secured.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0