Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE PINA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOSE PINA in 141 MARIA BLVD, ARCHBALD, PA 18403 (NAICS 238160). OSHA activity number 346399025.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Pina — free Get an email when a new federal OSHA severe-injury report for Jose Pina is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE PINA
Site address
141 MARIA BLVD
City
ARCHBALD
State
PA
ZIP
18403
Mailing
1408 D STREET, WOODBRIDGE, VA 22191
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.1053 B16

Serious Gravity 10 1 instance 9 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $5,156 · Current $5,156
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  a) Driveway access to Garage Roof: Employees were exposed to fall hazards due to a defective ladder with bent and damaged side rails being used to access the garage roof, on or about December 19, 2022.  Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $5156

1926.501 B13

Repeat Gravity 10 2 instances 9 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $10,313 · Current $10,313
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Main House Roof: Employees were exposed to fall hazards of approximately 20 (twenty) feet due to a lack of guardrail systems, safety net system, or personal fall arrest system, on or about December 19, 2022.  b) Garage Roof: Employees were exposed to fall hazards in excess of 9 (nine) feet due to a lack of guardrail systems, safety net system, or personal fall arrest system, on or about December 19, 2022.  The Employer, Jose Pina dba Pina Construction,  was previously cited for a violation of this occupational safety and health standard 1926.501(b)(13), which was contained in OSHA inspection number 1395138, citation number 1, item number 1, and was affirmed as a final order on September 4, 2019, with respect to a workplace located at 1480 Wyndham Drive, York, Pennsylvania 17403.  Abatement certification and documentation required.
Recent events (1)
  • — Z (R) $10313

1926.1053 B01

Repeat Gravity 10 2 instances 9 exposed
Issued
Apr 3, 2023
Abate by
Apr 13, 2023
Penalty
Initial $10,313 · Current $10,313
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) Front of Main House: Employees were subject to fall hazards while accessing the roof of the house due to a ladder that was not set-up so that its side rails extended 3 (three) feet past the upper landing surface, on or about December 19, 2022.  b) Garage: Employees were subject to fall hazards while accessing the roof of the garage due to a ladder that was not set-up so that its side rails extended 3 (three) feet past the upper landing surface, on or about December 19, 2022.   The employer, Jose Pina dba Pina Construction was previously cited for a violation of this occupational safety and health standard 1926.1053(b)(1), which was contained in OSHA inspection number 1395138, citation number 1, item number 3, and was affirmed as a final order on September 4, 2019, with respect to a workplace located at 1480 Wyndham Drive, York, PA 17403.  Abatement certification and documentation required.
Recent events (1)
  • — Z (R) $10313

View Jose Pina's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346399025.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.