Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ITW DELTAR FASTENERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ITW DELTAR FASTENERS in 1700 FIRST AVENUE, CHIPPEWA FALLS, WI 54729 (NAICS 326199). OSHA activity number 346404650.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ITW Deltar Fasteners — free Get an email when a new federal OSHA severe-injury report for ITW Deltar Fasteners is published. One employer, no account, unsubscribe in one click.
Site address
1700 FIRST AVENUE
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
1700 FIRST AVENUE, CHIPPEWA FALLS, WI 54729
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
225
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 18, 2023
Abate by
Jun 2, 2023
Penalty
Initial $9,209 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Building A, tool room; Energy isolation procedures for the Bridgeport milling machines were not utilized while employee(s) performed servicing activities of changing cutting tools or bits.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9209

1910.147 D03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 18, 2023
Abate by
Jun 2, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Building A, tool room; While performing servicing activities such as tool and bit changes on the Bridgeport milling machines, employee(s) did not isolate the electrical energy source by unplugging the power cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 18, 2023
Abate by
Jun 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Building A, tool room; While performing servicing activities such as tool and bit changes on the Bridgeport milling machines, employee(s) did not have a lockout device affixed to the power cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
May 18, 2023
Abate by
Jun 9, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:   (a) Building A; A record/certification of completion was not maintained to document that energy control (lockout/tagout) procedures were evaluated for equipment including, but not limited to, the Toshiba Injection Molding Machine # 114, Water heater (W173) for injection molding machine #248, Granulator (G18) for injection molding machine #144, and the Bridgeport milling machines.