OSHA Inspection: CONCURRENT GROUP LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CONCURRENT GROUP LLC in SW 107TH AVENUE AND 162ND TERRACE, MIAMI, FL 33157 (NAICS 221122). OSHA activity number 346419914.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Concurrent Group LLC — free Get an email when a new federal OSHA severe-injury report for Concurrent Group LLC is published. One employer, no account, unsubscribe in one click.
Site address
SW 107TH AVENUE AND 162ND TERRACE
City
MIAMI
State
FL
ZIP
33157
Mailing
475 SENTRY PARKWAY E SUITE 200, BLUE BELL, PA 19422
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.959 D01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 30, 2023
Abate by
Jul 20, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1926.959(d)(1): Mechanical equipment was operated so that the minimum approach distances established under 1926.960(c)(1)(I) were not maintained from exposed energized lines and equipment:  On or about 01/04/2023, on a worksite located at the intersection of SW 107th Avenue and 162nd Terrace in Miami, Florida, an employee was exposed to an electrocution hazard when operating a digger derrick truck within the minimum approach distance to energized 7,620-volt overhead power lines while those lines were not insulated.
Recent events (3)
  • — J (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1926.960 C01 III B

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 30, 2023
Abate by
Jul 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.960(c)(1)(iii)(B): The employer did not ensure energized parts were insulated when conductive objects were taken closer that the employers established minimum approach distance:   On or about 01/04/2023, on a worksite located at the intersection of SW 107th Avenue and 162nd Terrace in Miami, Florida, an employee was exposed to an electrocution hazard when operating a digger derrick truck within the minimum approach distance to energized 7,620-volt overhead power lines while those lines were not insulated.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.959 D02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 30, 2023
Abate by
Jul 20, 2023
Penalty
Initial $12,656 · Current $0 Reduced
29 CFR 1926.959(d)(2): The employer did not ensure that a designated employee other than the equipment operator observed the approach distance to exposed lines and equipment and provide timely warnings before the minimum approach distance required by paragraph (d)(1) of this section was reached:  On or about 01/04/2023, on a worksite located at the intersection of SW 107th Avenue and 162nd Terrace in Miami, Florida, an employee was exposed to electrocution hazards when the employer failed to ensure that an observer was designated to observe and warn the employee working near energized and uninsulated 7,620-volt overhead power lines before the minimum approach distance was reached.
Recent events (3)
  • — J (S) $0
  • — C (S) $12656
  • — Z (S) $12656

1926.959 D03 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 30, 2023
Abate by
Jul 20, 2023
Penalty
Initial $12,656 · Current $0 Reduced
29 CFR  1926.959(d)(3)(iii): The employer did not ensure that each employee was protected from hazards that could arise from mechanical equipment contact with energized lines or equipment by using the best available ground to minimize the time the lines or electric equipment remain energized:  On or about 01/04/2023, on a worksite located at the intersection of SW 107th Avenue and 162nd Terrace in Miami, Florida, an employee was exposed to electrocution hazards when the employer did not ensure that grounding of the equipment and insulating protective equipment was utilized before employees began working near an energized and uninsulated 7,620-volt overhead power line.
Recent events (3)
  • — J (S) $0
  • — C (S) $12656
  • — Z (S) $12656

1926.20 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 30, 2023
Abate by
Jul 20, 2023
Penalty
Initial $0 · Current $28,656
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)  a) On or about 01/04/2023, on a worksite located at the intersection of SW 107th Avenue and 162nd Terrace in Miami, Florida, employees were exposed to electrical hazards when working in close proximity to energized 7,620-volt overhead power lines and the employer had not performed an inspection of the site and equipment to ensure employees did not approach those lines.