DEERFIELD, WI —
OSHA Inspection: MPI ENGINEERED TECHNOLOGIES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MPI ENGINEERED TECHNOLOGIES LLC in 101 GRAND AVE, DEERFIELD, WI 53531 (NAICS 336370). OSHA activity number 346420375.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MPI ENGINEERED TECHNOLOGIES LLC
- Site address
- 101 GRAND AVE
- City
- DEERFIELD
- State
- WI
- ZIP
- 53531
- Mailing
- 101 N. GRAND AVENUE, DEERFIELD, WI 53531
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 320
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Jun 5, 2023
- Abate by
- Jul 21, 2023
- Penalty
- Initial $15,625 · Current $10,938 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 5, 2023, machine guarding was not provided to protect the operator from hazards including, but not limited to, point of operation, ingoing nip point, rotating parts, flying chips and sparks. a) The operator Wilhelmsburger Fineblanking press, Machine number 3222 was exposed to pinch point hazards created by the vertical movement of the lower die of the press. b) The operator of the Loher Drill press located in the Tool room was exposed to hazards from rotating parts, flying chips and sparks. c) The operator of the Ikeda Radial Drilling Machine MFG. NO. 87093 was exposed to hazards rotating parts, flying chips and sparks. d) The operator of the C Sip Hydroptic-6A Mill located in the Tool Room was exposed to hazards rotating parts, flying chips and sparks. e) The operator of the Moore precision grinder S/N G3657 was exposed to hazards rotating parts, flying chips and sparks. f) The operator of the 3 Bridgeport Mill's located in the Tool Room was exposed to hazards rotating parts, flying chips and sparks.
Recent events (2)
- — I (S) $10938
- — Z (S) $15625
More inspections at MPI Engineered Technologies LLC
View MPI Engineered Technologies LLC's full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346420375.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.