Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARIOTTI BUILDING PRODUCTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARIOTTI BUILDING PRODUCTS in 1 LOUIS INDUSTRIAL DRIVE, OLD FORGE, PA 18518 (NAICS 337110). OSHA activity number 346421175.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mariotti Building Products — free Get an email when a new federal OSHA severe-injury report for Mariotti Building Products is published. One employer, no account, unsubscribe in one click.
Site address
1 LOUIS INDUSTRIAL DRIVE
City
OLD FORGE
State
PA
ZIP
18518
Mailing
1 LOUIS INDUSTRIAL DRIVE, OLD FORGE, PA 18518
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
89
Ownership type
A

5 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 1 instance 10 exposed
Issued
May 1, 2023
Abate by
Jun 30, 2023
Penalty
Initial $4,687 · Current $3,600 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  a) Shop Yard - Employees operating the Holtec Crosscut Saw System were exposed to a fire hazard in that the emergency exit access route was less than twenty-eight (28) inches at all points, on or about January 6, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4687

1910.147 C06 I

Serious Gravity 5 1 instance 89 exposed
Issued
May 1, 2023
Abate by
May 11, 2023
Penalty
Initial $7,813 · Current $6,450 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Facility Wide - Employees conducting servicing and maintenance activities were exposed to amputation hazards in that the employer did not ensure that all energy control procedures were inspected at least annually, on or about January 6, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (S) $6450
  • — Z (S) $7813

1910.213 I01

Serious Gravity 5 1 instance 89 exposed
Issued
May 1, 2023
Abate by
May 11, 2023
Penalty
Initial $7,813 · Current $6,450 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  a) Fabrication Shop - Employees operating the Rockwell/Delta vertical bandsaw were exposed to amputation hazards in that the section of blade not in use was not guarded, on or about January 6, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (S) $6450
  • — Z (S) $7813

1904.40 A

Other-than-serious 1 instance 89 exposed
Issued
May 1, 2023
Abate by
May 11, 2023
Penalty
Initial $1,562 · Current $1,000 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  (a) Facility Wide - The employer did not provide the annual summary of work-related injury and illnesses for 2020 within four (4) hours of being requested, on or about January 6, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1562

1910.147 C07 IV

Other-than-serious 1 instance 89 exposed
Issued
May 1, 2023
Abate by
May 11, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  a) Facility Wide - The employer failed to certify that employees exposed to stored hazardous energy while conducting servicing and maintenance activities had been trained on the company's energy control procedures, on or about January 6, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mariotti Building Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346421175.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.