Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATCO STRUCTURES & LOGISTICS (USA) INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ATCO STRUCTURES & LOGISTICS (USA) INC. in 1106 NORTH TEMPLE DRIVE, DIBOLL, TX 75941 (NAICS 321992). OSHA activity number 346428444.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atco Structures & Logistics (USA) INC. — free Get an email when a new federal OSHA severe-injury report for Atco Structures & Logistics (USA) INC. is published. One employer, no account, unsubscribe in one click.
Site address
1106 NORTH TEMPLE DRIVE
City
DIBOLL
State
TX
ZIP
75941
Mailing
1106 NORTH TEMPLE DRIVE, DIBOLL, TX 75941
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321992
Employees
103
Ownership type
A

7 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 12 exposed
Issued
Feb 16, 2023
Abate by
Mar 15, 2023
Penalty
Initial $4,610 · Current $2,766 Reduced
29 CFR  1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about January 10, 2023, employees were exposed to respiratory hazards while wearing N95 filtering facepiece respirators when sanding in the flooring department without the employer having an established written respiratory protection program.
Recent events (2)
  • — I (S) $2766
  • — Z (S) $4610

1910.134 E01

Serious Gravity 1 1 instance 12 exposed
Issued
Feb 16, 2023
Abate by
Mar 15, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:(a)   On or about January 10, 2023, employees were exposed to respiratory hazards while wearing N95 filtering facepiece respirators when sanding in the flooring department without having been medically evaluated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 12 exposed
Issued
Feb 16, 2023
Abate by
Mar 15, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   On or about January 10, 2023, employees were exposed to respiratory hazards while wearing N95 filtering facepiece respirators when sanding in the flooring department without having been fit-tested before initial use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 16, 2023
Abate by
Feb 23, 2023
Penalty
Initial $4,610 · Current $2,766 Reduced
29 CFR  1910.138(a):The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.  On or�about January 10, 2023,�in the�flooring department, employees�were exposed�to chemical hazards�while they�mixed and used a cement based patch product without proper gloves.
Recent events (2)
  • — I (S) $2766
  • — Z (S) $4610

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 16, 2023
Abate by
Mar 15, 2023
Penalty
Initial $7,685 · Current $4,611 Reduced
29 CFR  1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or�about January 10, 2023,�employees were exposed�to corrosive chemical�hazards while�mixing and using a cement based patch product�without a�suitable eyewash.
Recent events (2)
  • — I (S) $4611
  • — Z (S) $7685

1910.303 B02

Serious Gravity 5 2 instances 12 exposed
Issued
Feb 16, 2023
Penalty
Initial $6,148 · Current $3,689 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. On or about January 10, 2023, in the floor department, employees were exposed to electrical hazards when powering a sander by using two extension cords plugged into each other, which is prohibited in the listing and labeling.  b. On or about January 10, 2023, in the floor department, employees were exposed to electrical hazards when powering a screw gun by using two extension cords plugged into each other, which is prohibited in the listing and labeling.
Recent events (2)
  • — I (S) $3688.8
  • — Z (S) $6148

1910.157 C01

Other-than-serious 1 instance 50 exposed
Issued
Feb 16, 2023
Abate by
Feb 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about January 10, 2023, employees were exposed to a fire hazard when portable fire extinguishers were not mounted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346428444.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.