EAST PROVIDENCE, RI —
OSHA Inspection: 3D SIDING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3D SIDING, INC. in 135 WATERMAN AVENUE, EAST PROVIDENCE, RI 02914 (NAICS 238170). OSHA activity number 346432248.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3D SIDING, INC.
- Site address
- 135 WATERMAN AVENUE
- City
- EAST PROVIDENCE
- State
- RI
- ZIP
- 02914
- Mailing
- 45 HAYDEN STREET, MARLBOROUGH, MA 01752
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1903.19 C01
- Issued
- Jun 29, 2023
- Abate by
- Aug 2, 2023
- Penalty
- Initial $376 · Current $263 Reduced
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of June 29, 2023, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Items 1b, 3a and 3b from inspection number 1643224, issued on 4/11/2023, with a final order date of 5/8/2023.
Recent events (3)
- — F (O) $263.2
- — C (O) $376
- — Z (O) $376
1903.19 D01
- Issued
- Jun 29, 2023
- Abate by
- Aug 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) Establishment: As of June 29, 2023 the employer had not provided the required abatement documentation to OSHA for Citation 1, Items 1b, 3a and 3b from inspection number 1643224, issued on 4/11/2023, with a final order date of 5/8/2023.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.451 C02
- Issued
- Apr 11, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation. (a) At the back of the building: On or about 1/10/2023, the employer allowed employees to assemble and use a pump jack scaffold system with the uprights resting on loose granular soil instead of base plates and mud sills or another adequate firm foundation.
Recent events (3)
- — F (S) $3281.6
- — C (S) $4688
- — Z (S) $4688
1926.451 F07
- Issued
- Apr 11, 2023
- Abate by
- May 25, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; such activities were not performed by experienced and trained employees selected for such work by the competent person. (a) At the back of the building: On or about 1/10/2023, the pump jack scaffold system was not erected by a trained experienced employee or under the supervision and direction of a competent person qualified in scaffold erection.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Apr 11, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section. (a) At the back of the building: On or about 1/10/2023, employees working from a pump jack scaffold system, approximately 25 feet above the lower level, were not protected from falling.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Apr 11, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a) At the back of the building: On or about 01-10-2023, the employer did not ensure that a pump jack scaffold system used by employees was secured to the structure by rigid triangular braces at the bottom of the scaffold.
Recent events (3)
- — F (S) $3281.6
- — C (S) $4688
- — Z (S) $4688
1926.454 A
- Issued
- Apr 11, 2023
- Abate by
- May 25, 2023
- Penalty
- Initial $4,688 · Current $3,282 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the back of the building: On or about 01-10-2023, employees were exposed to fall hazards while working from a pump jack scaffold system without the training necessary to recognize the hazards associated with this type of scaffold and the procedures to control or minimize the hazards.
Recent events (3)
- — F (S) $3281.6
- — C (S) $4688
- — Z (S) $4688
1926.454 B
- Issued
- Apr 11, 2023
- Abate by
- May 25, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. (a) At the back of the building: On or about 01-10-2023, the employer did not train employees involved in erecting, disassembling, moving, operating, maintaining or inspecting a pump jack scaffold system to recognize the hazards associated with the work being performed.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at 3D Siding, INC.
View 3D Siding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346432248.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.