Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UXBRIDGE CABINET CENTER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UXBRIDGE CABINET CENTER, INC. in 706 QUAKER HIGHWAY, UXBRIDGE, MA 01569 (NAICS 337110). OSHA activity number 346432651.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Uxbridge Cabinet Center, INC. — free Get an email when a new federal OSHA severe-injury report for Uxbridge Cabinet Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
706 QUAKER HIGHWAY
City
UXBRIDGE
State
MA
ZIP
01569
Mailing
706 QUAKER HIGHWAY, UXBRIDGE, MA 01569
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
20
Ownership type
A

1 citation on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 9 exposed
Issued
Feb 6, 2023
Abate by
Mar 24, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: 706 Quaker Highway, Uxbridge, MA:  On January 12, 2023 and for over two year prior, the employer had not performed a comprehensive periodic inspection of energy control procedures including, but not limited to the Ritter R19F3 Line Drill machine, at least annually, to verify that each procedure was adequate and being used properly by employees. *Abatement Notes:   A periodic inspection shall include the following elements:  -  Appointment of an authorized employee to inspect each unique energy control procedure for inaccuracies during an actual energy control task   -  A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use -  Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies.  Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act