UXBRIDGE, MA —
OSHA Inspection: UXBRIDGE CABINET CENTER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UXBRIDGE CABINET CENTER, INC. in 706 QUAKER HIGHWAY, UXBRIDGE, MA 01569 (NAICS 337110). OSHA activity number 346432651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UXBRIDGE CABINET CENTER, INC.
- Site address
- 706 QUAKER HIGHWAY
- City
- UXBRIDGE
- State
- MA
- ZIP
- 01569
- Mailing
- 706 QUAKER HIGHWAY, UXBRIDGE, MA 01569
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C06 I
- Issued
- Feb 6, 2023
- Abate by
- Mar 24, 2023
- Penalty
- Initial $3,572 · Current $3,572
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: 706 Quaker Highway, Uxbridge, MA: On January 12, 2023 and for over two year prior, the employer had not performed a comprehensive periodic inspection of energy control procedures including, but not limited to the Ritter R19F3 Line Drill machine, at least annually, to verify that each procedure was adequate and being used properly by employees. *Abatement Notes: A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each unique energy control procedure for inaccuracies during an actual energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act
Recent events (1)
- — Z (S) $3572
More inspections at Uxbridge Cabinet Center, INC.
View Uxbridge Cabinet Center, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346432651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.