TWENTYNINE PALMS MCB, CA —
OSHA Inspection: U.S. MARINE CORPS AIR GROUND COMBAT CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. MARINE CORPS AIR GROUND COMBAT CENTER in BUILDING 1502, 5TH STREET, TWENTYNINE PALMS MCB, CA 92278 (NAICS 452319). OSHA activity number 346436173.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. MARINE CORPS AIR GROUND COMBAT CENTER
- Site address
- BUILDING 1502, 5TH STREET
- City
- TWENTYNINE PALMS MCB
- State
- CA
- ZIP
- 92278
- Mailing
- MCAGCC - MCCS, BLDG. 1533 BOX 788150, TWENTYNINE PALMS MCB, CA 92278
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452319
- Employees
- 95
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.28 B01 I
- Issued
- Feb 22, 2023
- Abate by
- Mar 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): Firearm Invoice Storage Cage: On and/or before January 12, 2023, employees accessed and walked the top of the Firearms Vault which had an unprotected edge and was above 4 feet high from the next lower level to retrieve firearms documentation from storage. The employees did not use fall protection systems while accessing and moving in the area which potentially exposed the employees to approximately 18 foot fall hazards.
Recent events (1)
- — Z (S) $0
1910.23 C11
- Issued
- Feb 22, 2023
- Abate by
- Mar 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface. Firearm Invoice Storage Cage: On and/or before January 12, 2023, employees used fiberglass A-frame ladders to access the top of the Firearms Vault which had an unprotected edge and was above 4 feet from the next lower level to retrieve firearms documentation. The employer did not ensure ladders used extended at least 3 feet above the upper landing surface which potentially exposed the employees to approximately 18 foot fall hazards.
Recent events (1)
- — Z (S) $0
1910.23 B08
- Issued
- Feb 22, 2023
- Abate by
- Mar 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed. Firearm Invoice Storage Cage: On and/or before January 12, 2023, employees used fiberglass A-frame ladder(s) top steps to access the top of the Firearms Vault which had an unprotected edge and was above 4 feet high from next lower level to retrieve firearms documentation. The employer did not ensure the top steps on the ladders were prohibited from use in accordance with the ladder design which potentially exposed the employees to approximately 18 foot fall hazards.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Feb 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Administrative Bull Pen: Sign Area: On and/or before January 12, 2023, employees used a portable extension cord(s) as a source for permanent power to power items such as a Hewlett Packard Color Laser Jet M653 copier/printer to create advertisement signs used in the retail store. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Feb 22, 2023
- Abate by
- May 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. Reference: ANSI Z358.1 Emergency Eyewash and Shower Standard 5.4.6 The eyewash unit temperature delivered by emergency equipment should be 'tepid' (between 60�F (16�C) and 100�F(38�C)) which involves providing both hot and cold water to the unit and installing a mixing valve to blend the water to the desired temperature. Food Prep Station: On and/or before January 12, 2023, employees used corrosive cleaners such as Sysco Classic Germicidal Ultra Bleach to clean food preparation sink area. The emergency eye wash unit was designed to where the delivery of 'tepid' water could not be consistently achieved which potentially exposed the employees to retinal or corneal burns.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Marine Corps AIR Ground Combat Center
View U.S. Marine Corps AIR Ground Combat Center's full OSHA safety record →
More inspections in this industry (NAICS 452319)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346436173.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.