OSHA Inspection: SIMS UTILITY SERVICES, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SIMS UTILITY SERVICES, LLC in 2833 KELLYSVILLE ROAD, PRINCETON, WV 24739 (NAICS 517919). OSHA activity number 346438583.

Watch Sims Utility Services, LLC — free Get an email when a new federal OSHA severe-injury report for Sims Utility Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2833 KELLYSVILLE ROAD
City
PRINCETON
State
WV
ZIP
24739
Mailing
5008 PAWNEY RD, CROSSVILLE, TN 38572
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517919
Employees
5
Ownership type
A

3 citations on file for this inspection.

1910.67 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2679.00 · Current $2000.00 Reduced
29 CFR  1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, was not worn and attached to the boom or basket when working from an aerial lift.  (a) 2833 Kellysville Road, Princeton, WV: On January 11, 2023 an employee was working from an aerial lift assisting in the lashing of a new fiber optics line. The employee was not utilizing a personal fall arrest or travel restraint system, exposing them to a fall hazard.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2679

1910.268 I01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $12000.00 Reduced
29 CFR  1910.268(i)(1): Whenever there was exposure to possible high voltage electrical contact, the employer did not ensure that head protection is used by employees.    (a) 2833 Kellysville Road, Princeton, WV: On January 11, 2023 an employee was working in proximity to overhead primary powerlines from an aerial lift, assisting in the lashing of a new fiber optics line. The employer did not ensure the employee utilized head protection, exposing them to possible high voltage electrical contact.
Recent events (2)
  • — I (S) $12000
  • — Z (S) $15625

1910.268 B07

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2 or in (i) - (iii) of this section:   (a) 2833 Kellysville Road, Princeton, WV: On January 11, 2023 an employee was working in proximity to a 19,000 volt overhead power line from an aerial lift, assisting in the lashing of a new fiber optics line. The employee operated the equipment such that their body was within 36 inches of the electrically energized power line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

VERIZON

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346438583.