Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DANIEL'S AMISH COLLECTION, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DANIEL'S AMISH COLLECTION, LLC. in 9190 MASSILLON ROAD, DUNDEE, OH 44624 (NAICS 337122). OSHA activity number 346440092.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Daniel'S Amish Collection, LLC. — free Get an email when a new federal OSHA severe-injury report for Daniel'S Amish Collection, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
9190 MASSILLON ROAD
City
DUNDEE
State
OH
ZIP
44624
Mailing
9190 MASSILLON ROAD, DUNDEE, OH 44624
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337122
Employees
17
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 17, 2023
Abate by
Mar 29, 2023
Penalty
Initial $10,046 · Current $10,046
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.   a) On or about January 10, 2023, employees in the cut shop operating the SCM Olimpic K230 Evo edge bander were exposed to rotating/moving parts and unguarded end trimming unit saw blades due to open soundproof covers, thereby exposing employees to flying debris and caught-in hazards.
Recent events (2)
  • — I (S) $10046
  • — Z (S) $10046

1910.147 C04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 17, 2023
Abate by
Apr 5, 2023
Penalty
Initial $14,063 · Current $14,063
29 CFR  1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  a) On or about January 10, 2023, employees operating the SCM Olimpic K230 Evo edge bander failed to utilize control of hazardous energy procedures while engaged in servicing and/or maintenance activities, such as but not limited to re/filling glue, loading edge banding, unjamming and clearing debris, thereby exposing employees to caught-in and/or struck-by hazards.   b) On or about January 18, 2023, employees operating the Whirlwind cut-off saw failed to utilize control of hazardous energy procedures while engaged in servicing and/or maintenance activities, such as but not blade changes, thereby exposing employees to caught-in and/or struck-by hazards.
Recent events (2)
  • — I (S) $14063
  • — Z (S) $14063

1910.147 D

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 17, 2023
Abate by
Apr 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):  a) On or about January 10, 2023, employees were exposed to machine hazards associated with moving parts, pinch points, and unguarded saw blades during unjamming and clearing debris on the SCM Olimpic K230 Evo edge bander, located in the cut shop. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  b) On or about January 18, 2023, employees were exposed to machine hazards associated with moving parts and an unguarded saw blade during a blade change on the Whirlwind cut-off saw, located in the cut shop. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II D

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 17, 2023
Abate by
Apr 5, 2023
Penalty
Initial $14,063 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii)(D):Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  a) On or about January 10, 2023, the employer's written hazardous energy control procedures for the SCM Olimpic K230 Evo edge bander failed to include specific requirements for testing to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  b) On or about January 18, 2023, the employer's written hazardous energy control procedures for the Whirlwind cut-off saw failed to include specific requirements for testing to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14063

1910.147 C06 I

Serious Gravity 1 1 instance 17 exposed
Issued
Mar 17, 2023
Abate by
Apr 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about January 18, 2023, the employer did not conduct periodic lockout/tagout inspections at least annually to ensure that the energy control procedure and requirements of this standard were being followed by employees performing servicing and/or maintenance on machines and equipment throughout the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $14,063 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a)  On or about January 10, 2023, the employer did not ensure that each authorized employee operating the SCM Olimpic K230 Evo edge bander were trained in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control prior to performing servicing and/or maintenance activities such as, but not limited to loading edge banding, unjamming and clearing debris.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14063

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346440092.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.