Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE PROCTER & GAMBLE PAPER PRODUCTS COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE PROCTER & GAMBLE PAPER PRODUCTS COMPANY in 501 EASTMAN AVE, GREEN BAY, WI 54302 (NAICS 322291). OSHA activity number 346441447.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Procter & Gamble Paper Products Company — free Get an email when a new federal OSHA severe-injury report for The Procter & Gamble Paper Products Company is published. One employer, no account, unsubscribe in one click.
Site address
501 EASTMAN AVE
City
GREEN BAY
State
WI
ZIP
54302
Mailing
501 EASTMAN AVE, GREEN BAY, WI 54302
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322291
Employees
648
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 12, 2023
Abate by
Jun 20, 2023
Penalty
Initial $9,488 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii):  The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  (a)	On or about December 13, 2022 and thereafter, at an establishment located at 501 Eastman Avenue in Green Bay, Wisconsin, at Paper Machine 10F; the Alternative Method of Energy Control procedure did not address all energy sources, such as but not limited to hydraulic and pneumatic energy sources for the rail and program lift J hooks while employees were threading and tying the tail on the core shaft exposing employees to accidental/inadvertent restart of equipment.  (b)	On or about January 17, 2023, at an establishment located at 501 Eastman Avenue in Green Bay, Wisconsin, at Paper Machine 10F; the Alternative Method of Energy Control procedure did not provide alternative protective measures while employees were threading the tail by the plybonder and slitters.  The Pilz PSEN sl-1.0p 2.1 safety gate system was not used in accordance with the manufacturer's instructions to control hazardous energy.
Recent events (3)
  • — F (S) $0
  • — C (S) $9488
  • — Z (S) $9488

1910.261 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 12, 2023
Abate by
Jun 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.261(b)(1): Lockouts. Devices such as padlocks shall be provided for locking out the source of power at the main disconnect switch. Before any maintenance, inspection, cleaning, adjusting, or servicing of equipment (electrical, mechanical, or other) that requires entrance into or close contact with the machinery or equipment, the main power disconnect switch or valve, or both, controlling its source of power or flow of material, shall be locked out or blocked off with padlock, blank flange, or similar device.  (a)  On or about December 13, 2022, at an establishment located at 501 Eastman Avenue in Green Bay, Wisconsin, at Paper Machine 10F, lock out devices were not utilized during the tail tying activities to control each of the energy sources, such as but not limited to electrical, pneumatic, and hydraulic for the plybonder, slitter, inject rail, and J hook program lift.    (b)  On or about January 17, 2023, at an establishment located at 501 Eastman Avenue in Green Bay, Wisconsin, at Paper Machine 10F, lock out devices were not utilized during the tail tying activities to control each of the energy sources, such as but not limited to electrical, pneumatic, and hydraulic for the plybonder, slitter, inject rail, and J hook program lift.  One single lockout device was placed on a hinged guard which did not address all energy sources and was used in a manner which was not approved by the manufacturer.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View The Procter & Gamble Paper Products Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346441447.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.