Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PLANET FITNESS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PLANET FITNESS in 21 GATEWAY SHOPPING CENTER, EDWARDSVILLE, PA 18704 (NAICS 713940). OSHA activity number 346441629.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Planet Fitness — free Get an email when a new federal OSHA severe-injury report for Planet Fitness is published. One employer, no account, unsubscribe in one click.
Establishment
PLANET FITNESS
Site address
21 GATEWAY SHOPPING CENTER
City
EDWARDSVILLE
State
PA
ZIP
18704
Mailing
21 GATEWAY SHOPPING CENTER, EDWARDSVILLE, PA 18704
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713940
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $8,036 · Current $8,036
29 CFR  1910.36(g)(2): An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access:  a) Back storage room- On or about January 18, 2023, employees working in the back storage room were exposed to fire hazards from exit routes not being at least 28 inches wide.   Abatement certification required
Recent events (1)
  • — Z (S) $8036

1910.37 A03

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level:   a) Back storage room-  On or about January 18, 2023, employees working in the back storage room were exposed to fire hazards due to a box approximately forty-two (42) inches wide by eighty-seven (87) inches long and approximately twenty-four (24) inches from the exit door.   Abatement certification required
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $8,036 · Current $8,036
29 CFR  1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling:  a) Back storage room-  On or about January 18, 2023, employees working in the back storage room were exposed to an electrical hazard due to missing screws on the front cover of the main circuit breaker panel.  b) Back storage room- On or about January 18, 2023, employees working in the back storage room were exposed to an fire hazard due to a breaker slot being covered by tape.     Abatement certification required
Recent events (1)
  • — Z (S) $8036

1910.303 F02

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.   a) Back storage room-  On or about January 18, 2023, employees working in the back storage room were exposed to an electrical hazards due to the main circuit breaker panel not being legibly marked.   Abatement certification required
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $6,026 · Current $6,026
29 CFR  1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  a) Back storage room-  On or about January 18, 2023, employees working in the back storage room were exposed to an electric hazard due to boxes being placed in front of the main circuit breaker panel.  Abatement certification required
Recent events (1)
  • — Z (S) $6026

1910.305 B01 II

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 24, 2023
Penalty
Initial $8,036 · Current $8,036
29 CFR  1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:  a) Back storage room-  On or about January 18, 2023, employees working in the back storage room were exposed to an electrical hazard due to an unused opening not effectively closed on the B circuit breaker panel.  Abatement certification required