Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GRAVITY IGNITE LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAVITY IGNITE LLC in 256 MAIN STREET, WADSWORTH, OH 44281 (NAICS 339999). OSHA activity number 346444722.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gravity Ignite LLC — free Get an email when a new federal OSHA severe-injury report for Gravity Ignite LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GRAVITY IGNITE LLC
Site address
256 MAIN STREET
City
WADSWORTH
State
OH
ZIP
44281
Mailing
256 MAIN STREET, WADSWORTH, OH 44281
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 27, 2023
Abate by
May 11, 2023
Penalty
Initial $3,795 · Current $1,873 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On or about January 17, 2023 employees in the "Production Area" and "Laser Area" were exposed to an unexpected energizing, startup or release of stored energy while performing servicing or maintenance on the machines in these areas. The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections before employees performed servicing or maintenance on this machines including, but not limited to the MultiCam APEX 3R CNC Router, the MultiCam 5000 Series CNC Router, and the KERN Laser Systems OPTIFLEX.
Recent events (2)
  • — I (S) $1873
  • — Z (S) $3795

1910.305 G01 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 27, 2023
Penalty
Initial $2,277 · Current $1,135 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure   a) On or about January 17, 2023 employees were exposed to an electrical shock from damaged temporary wiring in the 15 area; the employer used flexible cords and/or cables as a substitute for fixed wiring.
Recent events (2)
  • — I (S) $1135
  • — Z (S) $2277

1910.305 G01 IV C

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(C): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be run through doorways, windows, or similar openings.   a) On or about January 17, 2023 employees were exposed to an electrical shock from damaged flexible cords in the 15 area; the employer did not ensure that all flexible cords and cables were protected from accidental damage from doorways or other pinch points.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 27, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket)  a) On or about January 17, 2023 employees were exposed to an electrical shock hazard of 120-volts from portable cords in the 15 area: the employer did not ensure to visually inspect the portable cord and plug connection for external defects and for evidence of possible internal damage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Mar 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6):The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  On or about January 17, 2023, the employer did not have certifications for a forklift operator that contained the date of training, the name of the operator, date of the evaluation, and identity of the person performing the training
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Gravity Ignite LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346444722.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.