Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HALCON GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HALCON GROUP in 2224 RICE BLVD, HOUSTON, TX 77005 (NAICS 238130). OSHA activity number 346447691.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Halcon Group — free Get an email when a new federal OSHA severe-injury report for Halcon Group is published. One employer, no account, unsubscribe in one click.
Establishment
HALCON GROUP
Site address
2224 RICE BLVD
City
HOUSTON
State
TX
ZIP
77005
Mailing
19901 SOUTHWEST FREEWAY, SUGAR LAND, TX 77498
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 16, 2023
Abate by
Jun 29, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR  1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  a) On or about January 19, 2023, on the south side of the residence, where an employee was exposed to a fall hazard greater than 6 feet while applying flashing tape from a pump jack scaffold where the end of the scaffold planking extended greater than 18 inches from the end of the scaffold.
Recent events (1)
  • — Z (S) $4465

1926.502 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 16, 2023
Abate by
Jun 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high.  a) On or about January 19, 2023, on the south side of the residence, where an employee was exposed to a fall hazard greater than 6 feet while applying flashing tape from a pump jack scaffold that was not equipped with a midrail.
Recent events (1)
  • — Z (S) $0

1926.451 F03

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 16, 2023
Abate by
Jun 29, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a) On or about January 19, 2023, on the south side of the residence, a pump jack scaffold used for applying flashing tape was not inspected prior to use.
Recent events (1)
  • — Z (S) $2678

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 16, 2023
Abate by
Jun 27, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  a) On or about January 19, 2023, on the south side of the residence, where an employee was exposed to a fall hazard greater than 6 feet while applying flashing tape from a pump jack scaffold without securing the scaffold poles at the bottom.
Recent events (1)
  • — Z (S) $4465

1926.501 B13

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 16, 2023
Penalty
Initial $4,465 · Current $4,465
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On or about January 19, 2023, on the south and west side of the residence where employees were exposed to a fall hazard greater than 6 feet when applying flashing from the roofing framework without a fall protection system.
Recent events (1)
  • — Z (S) $4465

View Halcon Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346447691.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.