Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN ROOFING AND HOME IMPROVEMENTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN ROOFING AND HOME IMPROVEMENTS in N83 W27750 CRESS BROOK CT., LISBON, WI 53089 (NAICS 238160). OSHA activity number 346448426.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Roofing and Home Improvements — free Get an email when a new federal OSHA severe-injury report for American Roofing and Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
N83 W27750 CRESS BROOK CT.
City
LISBON
State
WI
ZIP
53089
Mailing
2423 EMSLIE DR., WAUKESHA, WI 53188
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 17, 2023
Abate by
Feb 24, 2023
Penalty
Initial $4,688 · Current $3,750 Reduced
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.  (a) On or about January 20, 2023, at the construction site located at N83 W27750 Cress Brook Ct. Lisbon, WI 53029, employees were performing roofing activities on a single family residential home while working from a ladder jack scaffold system with no fall protection system in place and were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately eleven feet.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $4688

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Feb 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  (a) On or about January 20, 2023, at the construction site located at N83 W27750 Cress Brook Ct. Lisbon, WI 53029, employees were performing roofing activities on a single family residential home with no fall protection system in place and were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately eleven feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Other-than-serious Gravity 10 4 instances 4 exposed
Issued
Feb 17, 2023
Penalty
Initial $4,688 · Current $0 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  (a) On or about January 20, 2023, the portable ladder being used for access to the roof did not extend at least 3 feet above the upper landing area. This exposed employees to a fall hazard of approximately 11 feet.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4688

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346448426.