GULFPORT, MS —
OSHA Inspection: ANDREAS VALENTA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANDREAS VALENTA in 323 2ND ST, GULFPORT, MS 39501 (NAICS 238130). OSHA activity number 346448996.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANDREAS VALENTA
- Site address
- 323 2ND ST
- City
- GULFPORT
- State
- MS
- ZIP
- 39501
- Mailing
- 3005 57TH AVE, GULFPORT, MS 39501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B02
- Issued
- Mar 27, 2023
- Abate by
- Apr 18, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: (a) West side of home - On or about January 19, 2023, the employer did not ensure the makeshift wood scaffolding walkways were not 18 inches wide, exposing the employees to a fall hazard. (b) South side of home - On or about January 19, 2023, the employer did not ensure the makeshift wood scaffolding walkways were not 18 inches wide, exposing the employees to a fall hazard.
Recent events (1)
- — Z (S) $2679
1926.501 B13
- Issued
- Mar 27, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m), or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b) (a) West side of roof - On or about January 19, 2023, Mr. Mendosa were instructed to frame the roof without the use of fall protection, exposing them to fall hazards.
Recent events (1)
- — Z (S) $2679
1926.1053 B01
- Issued
- Mar 27, 2023
- Penalty
- Initial $2,009 · Current $2,009
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: (a) West side of the home - On or about January 19, 2023, the employer provided a 6-foot step ladder to access the roof that did not extend 3 feet past the roof edge exposing employees to fall hazards.
Recent events (1)
- — Z (S) $2009
1926.1053 B04
- Issued
- Mar 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) West side of the house - On or about January 19, 2023, the employer provided a 6-footstep ladder for the employees to access the roof, exposing employees to a fall hazard.
Recent events (1)