OSHA Inspection: ELECTRICAL INTEGRITY LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ELECTRICAL INTEGRITY LLC in 2600 LANCASTER AVENUE, WILMINGTON, DE 19805 (NAICS 238210). OSHA activity number 346449028.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electrical Integrity LLC — free Get an email when a new federal OSHA severe-injury report for Electrical Integrity LLC is published. One employer, no account, unsubscribe in one click.
Site address
2600 LANCASTER AVENUE
City
WILMINGTON
State
DE
ZIP
19805
Mailing
117 J AND M DRIVE, NEW CASTLE, DE 19720
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.502 E02

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Apr 25, 2023
Penalty
Initial $3,572 · Current $3,161 Reduced
29 CFR  1926.502(e)(2): Positioning devices were not secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever was greater:    a) 2600 Lancaster Avenue Wilmington, DE 19805 (Front of Building): On or about January 20, 2023, CSHO observed an employee operating a Sunbelt - JLG Industries, Inc Model 340AJ Serial #0300236668 while installing electrical equipment without an appropriate fall protection system and anchorage point while at heights of approxialety 10 feet.    In the alternative:  29 CFR  1926.502(d)(23): Personal fall arrest systems were attached to guardrail systems or to hoists:
Recent events (2)
  • — I (O) $3160.8
  • — Z (S) $3572

1926.454 A

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Apr 25, 2023
Penalty
Initial $3,572 · Current $3,161 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.   a) 2600 Lancaster Avenue Wilmington, DE 19805 (Front of Building): On or about January 20, 2023, the employer did not ensure each employee operating a Sunbelt - JLG Industries, Inc Model 340AJ Serial #0300236668 was trained to operate the articulating boom to meet manufactures specifications.
Recent events (2)
  • — I (O) $3160.8
  • — Z (S) $3572