WILMINGTON, DE —
OSHA Inspection: ELECTRICAL INTEGRITY LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ELECTRICAL INTEGRITY LLC in 2600 LANCASTER AVENUE, WILMINGTON, DE 19805 (NAICS 238210). OSHA activity number 346449028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELECTRICAL INTEGRITY LLC
- Site address
- 2600 LANCASTER AVENUE
- City
- WILMINGTON
- State
- DE
- ZIP
- 19805
- Mailing
- 117 J AND M DRIVE, NEW CASTLE, DE 19720
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 E02
- Issued
- Apr 25, 2023
- Penalty
- Initial $3,572 · Current $3,161 Reduced
General-duty citation text
29 CFR 1926.502(e)(2): Positioning devices were not secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever was greater: a) 2600 Lancaster Avenue Wilmington, DE 19805 (Front of Building): On or about January 20, 2023, CSHO observed an employee operating a Sunbelt - JLG Industries, Inc Model 340AJ Serial #0300236668 while installing electrical equipment without an appropriate fall protection system and anchorage point while at heights of approxialety 10 feet. In the alternative: 29 CFR 1926.502(d)(23): Personal fall arrest systems were attached to guardrail systems or to hoists:
Recent events (2)
- — I (O) $3160.8
- — Z (S) $3572
1926.454 A
- Issued
- Apr 25, 2023
- Penalty
- Initial $3,572 · Current $3,161 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) 2600 Lancaster Avenue Wilmington, DE 19805 (Front of Building): On or about January 20, 2023, the employer did not ensure each employee operating a Sunbelt - JLG Industries, Inc Model 340AJ Serial #0300236668 was trained to operate the articulating boom to meet manufactures specifications.
Recent events (2)
- — I (O) $3160.8
- — Z (S) $3572
More inspections in this industry (NAICS 238210)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346449028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.