Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIPLE P INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRIPLE P INC. in 1516 ATKINSON DR, GREEN BAY, WI 54303 (NAICS 327320). OSHA activity number 346450802.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triple P INC. — free Get an email when a new federal OSHA severe-injury report for Triple P INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TRIPLE P INC.
Site address
1516 ATKINSON DR
City
GREEN BAY
State
WI
ZIP
54303
Mailing
1516 ATKINSON DR, GREEN BAY, WI 54303
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
75
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 3 instances 3 exposed
Issued
Apr 26, 2023
Penalty
Initial $10,938 · Current $10,938
29 CFR  1910.28(b)(1)(i): (1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:  On or about January 13, 2023, at an establishment located at 1516 Atkinson Drive in Green Bay, Wisconsin, employees of Peters Concrete Company would step down onto a conveyor belt that has unprotected sides while being exposed to fall distances of 11 feet 6 inches.
Recent events (2)
  • — I (S) $10938
  • — Z (S) $10938

1910.147 C04 II

Serious Gravity 10 3 instances 3 exposed
Issued
Apr 26, 2023
Penalty
Initial $10,938 · Current $10,938
29 CFR  1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:   On or about January 13, 2023, at an establishment located at 1516 Atkinson Drive in Green Bay, Wisconsin, the energy control procedure for the loading conveyor did not provide for exclusive control of the lockout tagout device.  Employees placed the key of the equipment in a desk drawer accessible to other employees during servicing and maintenance tasks.  The control key does not provide for energy isolation of the machine or equipment.
Recent events (2)
  • — I (S) $10938
  • — Z (S) $10938

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 26, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about January 13, 2023, at an establishment located at 1516 Atkinson Drive in Green Bay, Wisconsin, an employee of Peters Concrete Company had not received training on energy control to identify the hazards associated with applicable energy source before performing servicing and maintenance tasks on a conveyor belt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 26, 2023
Penalty
Initial $10,938 · Current $0 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about January 13, 2023, employees were exposed to machine hazards associated with moving parts when they engaged in servicing and maintenance activities on the loading conveyor.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to reinstall insulation to fill the opening for the loading conveyor at the end of the workday.  The conveyor was not deenergized prior to the employee engaging in the servicing/maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10938

View Triple P INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346450802.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.