On , OSHA opened a referral safety inspection of WINNICK STEEL, INC. in 141 CANNON ROAD, WILTON, CT 06897 (NAICS 238120). OSHA activity number 346454176.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Winnick Steel, INC. — free Get an email when a new federal OSHA severe-injury report for Winnick Steel, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WINNICK STEEL, INC.
Site address
141 CANNON ROAD
City
WILTON
State
CT
ZIP
06897
Mailing
820 WOODEND ROAD, STRATFORD, CT 06615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
25
Ownership type
A

2 citations on file for this inspection.

1926.755 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 11, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1926.755(b)(1):Anchor rods (anchor bolts) shall not be repaired, replaced or field-modified without the approval of the project structural engineer of record.  Worksite: On or about January 20, 2023, the employer did not ensure that all steel beam support columns were installed to prevent tip over or collapse in that the column erection plan was changed by the employer without notice or approval to the engineer of record.  An employee sustained severe injuries after a column tipped and crashed through the floor he was working from.
Recent events (1)
  • — Z (S) $6250

1926.755 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 11, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.755(a)(1):Columns were not anchored by a minimum of four anchor bolts.  Worksite: On or about January 20, 2023, the employer did not ensure that all steel beam support columns were installed to prevent tip over or collapse.   An employee sustained severe injuries after a column tipped and crashed through the floor he was working from.