OSHA Inspection: U.S. DEPT. OF THE ARMY

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of U.S. DEPT. OF THE ARMY in 6695 101ST AIRBORNE DIVISION RD DPW LANDFILL, FORT CAMPBELL, KY 42223 (NAICS 928110). OSHA activity number 346456049.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of the Army — free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of the Army is published. One employer, no account, unsubscribe in one click.
Site address
6695 101ST AIRBORNE DIVISION RD DPW LANDFILL
City
FORT CAMPBELL
State
KY
ZIP
42223
Mailing
BLDG 6074 SCREAMING EAGLE BLVD, FORT CAMPBELL, KY 42223
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
5
Ownership type
D

3 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 5, 2023
Abate by
Jul 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a) Building 6695, North wall,  left of rear exit door, employer exposed employees to death and fire related injuries, in that the pathway to the rear exit door was obstructed by a Frigidaire electric stove.
Recent events (1)
  • — Z (S) $0

1910.36 G04

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 5, 2023
Abate by
Jul 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.36(g)(4): Objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes.  (a) Building 6695, North wall,  left of rear exit door, employer exposed employees to death and fire related injuries, in that the pathway to the rear exit door was reduced to a width of 15 inches which is less than the required 28 inch minimum for a building with at least two exits.
Recent events (1)
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 5, 2023
Abate by
Jul 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casings enclosing shafting completely:   (a): Vicinity of DPW Landfill on Fort Campbell, KY: On or about 1/24/2023, and at times prior, employer exposed employees to caught in and amputation hazard, in that , the rotating shaft casing connecting a Kubota M6 tractor and a pull behind rotary cutter, was not protected with a PTO cover.  (b): Vicinity of DPW Landfill on Fort Campbell, KY: On or about 1/24/2023, and at times prior, employer exposed employees to caught in and amputation hazard, in that , the rotating shaft casing connecting the center shaft of pull behind rotary cutter to the left cutting wing, was not protected with a PTO cover.
Recent events (1)
  • — Z (S) $0