OSHA Inspection: NAF MORALE, WELFARE, AND RECREATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAF MORALE, WELFARE, AND RECREATION in 625 MAMALA BAY DRIVE, JOINT BASE PEARL HBR HICKAM, HI 96853 (NAICS 713910). OSHA activity number 346457740.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NAF Morale, Welfare, and Recreation — free Get an email when a new federal OSHA severe-injury report for NAF Morale, Welfare, and Recreation is published. One employer, no account, unsubscribe in one click.
Site address
625 MAMALA BAY DRIVE
City
JOINT BASE PEARL HBR HICKAM
State
HI
ZIP
96853
Mailing
625 MAMALA BAY DRIVE, JOINT BASE PEARL HBR HICKAM, HI 96853
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713910
Employees
20
Ownership type
D

6 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 21, 2023
Abate by
Mar 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Employees required to use a half-face respirator when diluting chemicals into a sprayer were not medically evaluated prior to respirator use.  Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2023
Abate by
Mar 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Employees required to use a half-face respirator when diluting chemicals into a sprayer without being fit tested prior to respirator use.  Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2023
Abate by
Mar 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Cart Barn/New and Used Battery Holding Area:  Employees were not provided with facilities for quick drenching or flushing of the eyes while working with golf cart batteries containing corrosive acid. Employees were exposed to chemical hazards.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Maintenance Shop: The floor mounted Wilton drill press did not have a chuck guard. Employees were exposed to rotating part hazards.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Maintenance Shop: The work rest for the 8" bench grinder was half an inch away from the grinding wheel. Employees were exposed to caught-in hazards.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Cart Barn/Employee Lounge Area Under Safety Board: A microwave plugged into a relocatable power tap that was connected in series (daisy chained) with another relocatable power tap. Employees were exposed to fire and electrical hazards.