JOINT BASE PEARL HBR HICKAM, HI —
OSHA Inspection: NAF MORALE, WELFARE, AND RECREATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NAF MORALE, WELFARE, AND RECREATION in 625 MAMALA BAY DRIVE, JOINT BASE PEARL HBR HICKAM, HI 96853 (NAICS 713910). OSHA activity number 346457740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAF MORALE, WELFARE, AND RECREATION
- Site address
- 625 MAMALA BAY DRIVE
- City
- JOINT BASE PEARL HBR HICKAM
- State
- HI
- ZIP
- 96853
- Mailing
- 625 MAMALA BAY DRIVE, JOINT BASE PEARL HBR HICKAM, HI 96853
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713910
- Employees
- 20
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Feb 21, 2023
- Abate by
- Mar 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Employees required to use a half-face respirator when diluting chemicals into a sprayer were not medically evaluated prior to respirator use. Employees were exposed to respiratory hazards.
Recent events (1)
- — Z (S) $0
1910.134 F02
- Issued
- Feb 21, 2023
- Abate by
- Mar 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Employees required to use a half-face respirator when diluting chemicals into a sprayer without being fit tested prior to respirator use. Employees were exposed to respiratory hazards.
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Feb 21, 2023
- Abate by
- Mar 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Cart Barn/New and Used Battery Holding Area: Employees were not provided with facilities for quick drenching or flushing of the eyes while working with golf cart batteries containing corrosive acid. Employees were exposed to chemical hazards.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Feb 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Maintenance Shop: The floor mounted Wilton drill press did not have a chuck guard. Employees were exposed to rotating part hazards.
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Feb 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Maintenance Shop: The work rest for the 8" bench grinder was half an inch away from the grinding wheel. Employees were exposed to caught-in hazards.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Feb 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Cart Barn/Employee Lounge Area Under Safety Board: A microwave plugged into a relocatable power tap that was connected in series (daisy chained) with another relocatable power tap. Employees were exposed to fire and electrical hazards.
Recent events (1)
- — Z (S) $0
More inspections at NAF Morale, Welfare, and Recreation
View NAF Morale, Welfare, and Recreation's full OSHA safety record →
More inspections in this industry (NAICS 713910)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346457740.