DERRY, PA —
OSHA Inspection: KEYSTONE FOAM CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KEYSTONE FOAM CORPORATION in 5358 PA 982, DERRY, PA 15627 (NAICS 326299). OSHA activity number 346462534.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE FOAM CORPORATION
- Site address
- 5358 PA 982
- City
- DERRY
- State
- PA
- ZIP
- 15627
- Mailing
- 5358 PA 982, DERRY, PA 15627
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Jul 7, 2023
- Abate by
- Aug 2, 2023
- Penalty
- Initial $10,938 · Current $5,600 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Jobsite, 5358 PA 982 Derry, PA 15627: On or about January 26, 2023, employees required to clean the carousel foam cutting machine tables and blade rollers and employees required to change the carousel cutting machine blades were not trained as Authorized employees under the employer's energy control program.
Recent events (2)
- — I (S) $5600
- — Z (S) $10938
1910.147 C07 IV
- Issued
- Jul 7, 2023
- Abate by
- Aug 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: a) Jobsite, 5358 PA 982 Derry, PA 15627: On or about January 26, 2023, the employer did not certify that employee training in lock out tag out had been accomplished and up to date. The employer did not maintain a certification of training including the employee's name and the date of training for each employee including those who are required to change the blades on the front and back carousel foam cutting machines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jul 7, 2023
- Abate by
- Aug 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Jobsite, 5358 PA 982 Derry, PA 15627: On or about January 26, 2023, the employer did not conduct periodic inspections of their energy control program and procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Keystone Foam Corporation
View Keystone Foam Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346462534.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.