Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FELIPE'S ROOFING & HOME IMPROVEMENT CORP.,

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FELIPE'S ROOFING & HOME IMPROVEMENT CORP., in 138 N. GARFIELD ST., HINSDALE, IL 60521 (NAICS 238160). OSHA activity number 346464241.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Felipe'S Roofing & Home Improvement Corp., — free Get an email when a new federal OSHA severe-injury report for Felipe'S Roofing & Home Improvement Corp., is published. One employer, no account, unsubscribe in one click.
Site address
138 N. GARFIELD ST.
City
HINSDALE
State
IL
ZIP
60521
Mailing
225 S WILMETTE AVE, WESTMONT, IL 60559
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 C02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 28, 2023
Abate by
May 15, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR  1926.451(c)(2)(iv):Front-end loaders and similar pieces of equipment shall not be used  to support scaffold platforms without being specifically designed by the manufacturer for such use.  On or about January 24, 2023,  an employee used a field designed wooden platform on a GEHL RS5-34 Telescopic lift in excess of 20 feet high as a scaffold platform for personnel residential roofing activities. The GEHL RS5-34 Telescopic lift was not designed to be used to lift personnel without the machine being  equipped with personnel work platform safety system.   Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $4688

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Apr 28, 2023
Penalty
Initial $9,375 · Current $9,375
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.    On or about January 24, 2023, Employees were exposed to fall hazards in excess of 20 feet while engaged in residential roofing activities. Fall protection was not being utilized while employees were engaged in roof installation activities.   No abatement certification or documentation is required for this item.  Felipe's Roofing & Home Improvement Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1587696, citation number 1 , item number 2  and was affirmed as a final order on October 7, 2022, with respect to a workplace located at 926 Greenwood Ave., Wilmette, IL. 60091.
Recent events (1)
  • — Z (R) $9375

1926.1053 B01

Repeat Gravity 5 1 instance 4 exposed
Issued
Apr 28, 2023
Penalty
Initial $6,697 · Current $6,697
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about January 24, 2023, the portable ladder used to access the roof level did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to fall hazards in excess of 15 feet.  No abatement certification or documentation is required for this item.  Felipe's Roofing & Home Improvement Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1587696, citation number 1 , item number 4  and was affirmed as a final order on October 7, 2022, with respect to a workplace located at 926 Greenwood Ave., Wilmette, IL. 60091.
Recent events (1)
  • — Z (R) $6697

View Felipe'S Roofing & Home Improvement Corp.,'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346464241.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.