OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PRO Solar Caribbean — free Get an email when a new federal OSHA severe-injury report for PRO Solar Caribbean is published. One employer, no account, unsubscribe in one click.
Establishment
PRO SOLAR CARIBBEAN
Site address
7411 ESTATE BOVONI BAY 309
City
ST THOMAS
State
VI
ZIP
00802
Mailing
7411 ESTATE BOVONI BAY 309, ST THOMAS, VI 00802
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
21
Ownership type
A

4 citations on file for this inspection.

1910.37 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 12, 2023
Abate by
Aug 2, 2023
Penalty
Initial $4,465 · Current $2,750 Reduced
29 CFR  1910.37(a)(1): The evacuation route contained hazardous and or flammable chemicals.  (a) On or about 01/24/2023, at  7411 Estate Bovoni Bay 309 St Thomas,  00802 - Pro Solar Office and Warehouse, the employer did not ensure the exit door was free of hazardous and or flammable chemicals, exposing employees to fire hazards.   NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
  • — I (S) $2750
  • — Z (S) $4465

1910.37 A03

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 12, 2023
Abate by
Aug 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed. Materials were placed, either permanently or temporarily, within the exit route:  (a) On or about 01/24/2023, at  7411 Estate Bovoni Bay 309 St Thomas,  00802 - Pro Solar Office and Warehouse, the employer did not ensure the exit door was unobstructed, exposing employees to fire hazards.   NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 12, 2023
Abate by
Aug 2, 2023
Penalty
Initial $4,465 · Current $2,750 Reduced
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) On or about 01/24/2023, at  7411 Estate Bovoni Bay 309 St Thomas,  00802 - Pro Solar Office and Warehouse, a 33.5 Lb Propane flammable gas cylinder was not stored in a secured area to avoid being struck or damaged, exposing employees to fire and explosion hazards. (b) On or about 01/24/2023, at  7411 Estate Bovoni Bay 309 St Thomas,  00802 - Pro Solar Office and Warehouse, a 20 Lb Propane flammable gas cylinder was not stored in a secured area to avoid being struck or damaged, exposing employees to fire and explosion hazards.  NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $2750
  • — Z (S) $4465

1910.334 A02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 12, 2023
Abate by
Jul 19, 2023
Penalty
Initial $3,572 · Current $1,500 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug-connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) On or about 01/24/2023, at  7411 Estate Bovoni Bay 309 St Thomas,  00802 - outside of the warehouse adjacent to the fire exit, a Nissan Electric Vehicle was being charged with a cord that had each of the electrical splices and conductors exposed creating an electrical hazard for employees.   NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3572

View PRO Solar Caribbean's full OSHA safety record →