Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPECTOR METAL PRODUCTS CO, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SPECTOR METAL PRODUCTS CO, INC. in 608 SOUTH STREET, HOLBROOK, MA 02343 (NAICS 331110). OSHA activity number 346470917.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spector Metal Products CO, INC. — free Get an email when a new federal OSHA severe-injury report for Spector Metal Products CO, INC. is published. One employer, no account, unsubscribe in one click.
Site address
608 SOUTH STREET
City
HOLBROOK
State
MA
ZIP
02343
Mailing
608 SOUTH STREET, HOLBROOK, MA 02343
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 15, 2023
Abate by
Aug 7, 2023
Penalty
Initial $3,349 · Current $2,344 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Location: Fabrication Shop  On or about  January 31, 2023, employees were exposed to un-guarded rotating parts on the following machines; a) Employees were exposed to the unused portion of blade on the Hydmech horizontal band saw, that was not guarded. b) Employees were exposed to the rotating vertical shafts on the Cleereman drill press, that was not guarded.
Recent events (2)
  • — I (S) $2344.3
  • — Z (S) $3349

1910.215 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 15, 2023
Abate by
Jul 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(a)(4):Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:(a)   Location: Fabrication  On or about April 7, 2023, the Ryobi bench grinder was used with the work rest 1/2 inch from the left abrasive wheel and 3/4 inch from the right from the right abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 15, 2023
Abate by
Jul 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   Location: Fabrication  On or about  April 7, 2023, the Ryobi bench grinder was used with the tongue guard 3/4 inch from the left abrasive wheel and 1-3/4 inch from the right abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 4 exposed
Issued
Jun 15, 2023
Abate by
Jul 24, 2023
Penalty
Initial $2,009 · Current $1,406 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a. Location: Fabrication, outside office door: On or about January 31, 2023, an electrical cabinet had an unused breaker opening  that was not covered.  b. Location: Fabrication, behind punch press: On or about January 31, 2023, an electrical cabinet had an unused breaker opening that was not covered.
Recent events (2)
  • — I (S) $1406.3
  • — Z (S) $2009

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Jun 15, 2023
Abate by
Jul 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  Location: Fabrication  On or about April 7. 2023, the employer did not certify in writing that forklift training and evaluation for employees operating the Clark fork lift truck, had been provided.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Jun 15, 2023
Abate by
Jul 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Location: Fabrication, behind punch machine   On or about January 31, 2023, materials and equipment were stored in front of an electrical circuit breaker box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Spector Metal Products CO, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346470917.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.