OSHA Inspection: BOCCARD PIPE FABRICATORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BOCCARD PIPE FABRICATORS, INC. in 2500 GALVESTON RD., HOUSTON, TX 77017 (NAICS 332996). OSHA activity number 346472228.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boccard Pipe Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Boccard Pipe Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2500 GALVESTON RD.
City
HOUSTON
State
TX
ZIP
77017
Mailing
2500 GALVESTON RD., HOUSTON, TX 77017
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.141 C02 I

Serious Gravity 1 1 instance 40 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $4,687 · Current $3,281 Reduced
29 CFR 1910.141(c)(2)(i): Each water closet did not occupy a separate compartment with a door and walls or partitions between fixtures sufficiently high to assure privacy:  a) At the work site, employer did not have separated compartments with walls or partition to assure privacy for employees when utilizing toilets and/or urinals.
Recent events (2)
  • — I (S) $3280.9
  • — Z (S) $4687

1910.179 J02 VI

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $9,376 · Current $6,563 Reduced
29 CFR 1910.179(j)(2)(vi):  The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:  All functional operating mechanisms for excessive wear of components.  a) At the worksite in Bay #4, the KCI 2-ton crane, was observed to have a safety latch that was inoperable on the crane hook exposing employees to a struck by hazard.
Recent events (2)
  • — I (S) $6563.2
  • — Z (S) $9376

1910.179 L03 III D

Serious Gravity 5 3 instances 15 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $9,376 · Current $6,563 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:  a) At the work location in Bay 2, where the pendant control for the 5-ton overhead crane did not have a legible labels.   b) At the work location in Bay 4, where the pendant control for the 2-ton overhead crane did not have a legible labels.   c) At the work location in Bay 5, where the pendant control for the 2-ton overhead crane did not have a legible labels.
Recent events (2)
  • — I (S) $6563.2
  • — Z (S) $9376

1910.252 B02 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $9,376 · Current $6,563 Reduced
29 CFR 1910.252(b)(2)(i)(A): During arc welding or arc cutting operations, helpers or attendants were not provided with proper eye protection:  a) At the worksite, while assisting in arc welding operation, an employee was not provided proper eye protection.
Recent events (2)
  • — I (S) $6563.2
  • — Z (S) $9376

1910.303 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $6,250 · Current $4,375 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) On the worksite, within the supply room, the circuit breaker box had no markings/labels to identify ratings, purpose, etc. leaving employees exposed to an electrical hazards.
Recent events (2)
  • — I (S) $4375
  • — Z (S) $6250

1910.303 G01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $9,376 · Current $6,563 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) On the worksite, within the supply room, there were several items blocking access to the electrical equipment and required working space.
Recent events (2)
  • — I (S) $6563.2
  • — Z (S) $9376

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $6,250 · Current $4,375 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:  a) At the worksite, where the strain relief on the black and yellow flexible cord was damaged.
Recent events (2)
  • — I (S) $4375
  • — Z (S) $6250

View Boccard Pipe Fabricators, INC.'s full OSHA safety record →