BANGOR, ME —
OSHA Inspection: WEBB'S RV CENTER
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WEBB'S RV CENTER in 1206 HAMMOND STREET, BANGOR, ME 04401 (NAICS 441210). OSHA activity number 346477193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEBB'S RV CENTER
- Site address
- 1206 HAMMOND STREET
- City
- BANGOR
- State
- ME
- ZIP
- 04401
- Mailing
- 1206 HAMMOND STREET, BANGOR, ME 04401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441210
- Employees
- 16
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.28 B01 I
- Issued
- May 9, 2023
- Abate by
- Jun 27, 2023
- Penalty
- Initial $10,938 · Current $5,469 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): Throughout the Workshop - The employer did not ensure that employees working on trailer and vehicle roofs with unprotected sides or edges 8-12 feet above a lower level were protected from falling.
Recent events (2)
- — I (S) $5469
- — Z (S) $10938
1910.157 E02
- Issued
- May 9, 2023
- Abate by
- Jun 5, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Throughout the Building - The employer did not ensure that portable fire extinguishers were visually inspected on a monthly basis.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.178 A04
- Issued
- May 9, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Workshop Bay 1 - Employer did not obtain the manufacturer's written approval before using a front-end ball-hitch attachment, which could affect the capacity and safe operation of a Hyundai 30L-7A powered industrial truck.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.178 A05
- Issued
- May 9, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): Powered industrial truck(s) equipped with front-end attachments, other than factory installed attachments, were not marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: Workshop Bay 1 - The Hyundai 30L-7A powered industrial truck, with a ball-hitch attachment, was not marked to identify the attachment and the approximate weight of the powered industrial truck and attachment combination at maximum elevation with load laterally centered.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- May 9, 2023
- Abate by
- Aug 9, 2023
- Penalty
- Initial $10,938 · Current $5,469 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): Throughout the Workshop - The employer did not certify that the operators, of a Hyundai 30L-7A forklift, had been trained and evaluated.
Recent events (2)
- — I (S) $5469
- — Z (S) $10938
1910.303 G01 II
- Issued
- May 9, 2023
- Abate by
- Jun 27, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Unlabeled, Behind Service Counter Beside Exterior Exit Door - Tires and boxes were stored in front of the electrical equipment. b) PNL-P2, Workshop Bay 1, Nearby Exterior Exit Door - A box and parts were stored in front of the electrical equipment.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.303 B02
- Issued
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with instructions included in the listing and labeling: Listed or labeled equipment was not installed and/or used correctly, in the following instances: a) Workshop Bay 1, Rear Right Corner - The electrical panel door was not closed, as required by the listing and labeling. b) Service Counter, Rear Right Side - The electrical panel door was not closed, as required by the listing and labeling. c) Store Front, Office Aisle, Log Column - Extension cords were connected to and from a relocatable power tap (RPT).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- May 9, 2023
- Penalty
- Initial $7,813 · Current $3,907 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Store Floor, Behind Column - The outlet box, with live wires, did not have a cover plate.
Recent events (2)
- — I (S) $3906.5
- — Z (S) $7813
1910.1200 E01
- Issued
- May 9, 2023
- Abate by
- Jun 27, 2023
- Penalty
- Initial $4,687 · Current $2,344 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Webb's RV Center - The employer did not develop or implement a written hazard communication program.
Recent events (2)
- — I (S) $2343.5
- — Z (S) $4687
1910.215 A04
- Issued
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: Workshop Bay 1 - Employees used a DeWalt bench grinder that did not have a work rest to support offhand grinding.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- May 9, 2023
- Abate by
- Jun 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors: Store Front Offices, On Column Across the Aisle - The employer had a flexible cord and cables run through a wall.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV C
- Issued
- May 9, 2023
- Abate by
- Jun 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure where run through doorways, windows, or similar openings: Store Front Offices, On Column Across the Aisle - The employer had a flexible cord and cables installed through a hole in the wall, in lieu of fixed wiring.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Webb'S RV Center
View Webb'S RV Center's full OSHA safety record →
More inspections in this industry (NAICS 441210)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346477193.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.