COLORADO SPRINGS, CO —
OSHA Inspection: ELITE STUCCO WALL SYSTEMS, INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ELITE STUCCO WALL SYSTEMS, INC in 93 CLEAR PASS VIEW, COLORADO SPRINGS, CO 80921 (NAICS 236116). OSHA activity number 346478431.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELITE STUCCO WALL SYSTEMS, INC
- Site address
- 93 CLEAR PASS VIEW
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80921
- Mailing
- 118 BUCHANAN STREET, COLORADO SPRINGS, CO 80907
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F07
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; such activities were not performed only by experienced and trained employees selected for such work by the competent person: (a) On or before 2/2/2023, the employer did not ensure that scaffolds were erected under the supervision of a competent person qualified in the erection, moving, dismantling, alteration of scaffolds. This condition exposed employees to scaffold collapse and fall hazards.
Recent events (1)
- — Z (S) $10938
1926.452 C02
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): All cross braces were not of such length so as to automatically square and align vertical members such that the erected scaffold was always plumb, level, and square: (a) On or before 2/2/2023, the employer did not ensure that scaffold cross members fit in such a way as to make the vertical members square and plumb. The cross braces were too long, were secured with wire and not pinned to the scaffold uprights as required by this standard. This condition exposed employees to scaffold collapse and fall hazards.
Recent events (1)
- — Z (S) $0
1926.452 C03
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: (a) On or before 2/2/2023, the employer did not ensure that scaffold frame sections were pinned or otherwise secured as required by this standard. This condition exposed employees to scaffold collapse and fall hazards.
Recent events (1)
- — Z (S) $0
1926.454 A
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: (a) On or before 2/2/2023, the employer did not ensure that all employees who would be working on the tubular frame scaffolds to install architectural stone were trained to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. This condition exposed employees to scaffold collapse and fall hazards.
Recent events (1)
- — Z (S) $0
1926.454 B
- Issued
- Mar 2, 2023
- Abate by
- Mar 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: (a) On or before 2/2/2023, the employer did not ensure that employees engaged in scaffold erection were trained by a competent person. Tubular welded scaffolds were improperly erected. This condition exposed employees to scaffold collapse and fall hazards.
Recent events (1)
- — Z (S) $0
More inspections at Elite Stucco Wall Systems, INC
View Elite Stucco Wall Systems, INC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346478431.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.