ASHLAND, WI —
OSHA Inspection: DELTCO OF WISCONSIN, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DELTCO OF WISCONSIN, INC. in 601 INDUSTRIAL PARK ROAD, ASHLAND, WI 54806 (NAICS 325211). OSHA activity number 346481054.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELTCO OF WISCONSIN, INC.
- Site address
- 601 INDUSTRIAL PARK ROAD
- City
- ASHLAND
- State
- WI
- ZIP
- 54806
- Mailing
- 601 INDUSTRIAL PARK ROAD, ASHLAND, WI 54806
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 100
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.28 B01 I
- Issued
- May 19, 2023
- Abate by
- Jul 28, 2023
- Penalty
- Initial $7,969 · Current $5,578 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i)(A)-(C): (a) Main Plant, EREMAs (1-3); Employees working on the EREMA platforms near the tippers, were exposed to falls greater than 4 feet, no means of fall protection was provided. (b) South Plant, Densifiers; Employees working on the densifier platforms near the tippers, were exposed to falls greater than 4 feet, no means of fall protection was provided.
Recent events (2)
- — I (S) $5578.3
- — Z (S) $7969
1910.95 G06
- Issued
- May 19, 2023
- Abate by
- May 30, 2023
- Penalty
- Initial $3,984 · Current $2,789 Reduced
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: (a) Main Plant; Annual audiograms were not performed for employees exposed to noise levels at or above an 8-hour time-weighted average of 85 decibels. The last audiograms were conducted in 2021. (b) South Plant; Annual audiograms were not performed for employees exposed to noise levels at or above an 8-hour time-weighted average of 85 decibels. The last audiograms were conducted in 2021.
Recent events (2)
- — I (S) $2788.8
- — Z (S) $3984
1910.147 C04 II
- Issued
- May 19, 2023
- Abate by
- Aug 25, 2023
- Penalty
- Initial $6,641 · Current $4,649 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) Main Plant; The facility did not have machine specific energy control procedures to include types and magnitude of energy, hazards, methods to control the energy, location of machine operating controls and energy isolating devices, types of stored energy and methods to dissipate, and methods of verifying isolation for equipment including, but not limited to, the EREMAs (1-3), Blenders (1&2), Extruders (A, B, D), and the tippers. (b) South Plant; The facility did not have machine specific energy control procedures to include types and magnitude of energy, hazards, methods to control the energy, location of machine operating controls and energy isolating devices, types of stored energy and methods to dissipate, and methods of verifying isolation for equipment including, but not limited to, the densifiers, tippers, shears, and the balers.
Recent events (2)
- — I (S) $4648.7
- — Z (S) $6641
1910.212 A01
- Issued
- May 19, 2023
- Abate by
- Jul 12, 2023
- Penalty
- Initial $5,313 · Current $3,719 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Main Plant, EREMA #3; The moving paddles of the conveyor section were not adequately guarded.
Recent events (2)
- — I (S) $3719.1
- — Z (S) $5313
More inspections at Deltco of Wisconsin, INC.
View Deltco of Wisconsin, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346481054.