Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OMNI CABLE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OMNI CABLE, LLC in 3350 LISBON STREET, AURORA, CO 80011 (NAICS 517911). OSHA activity number 346485758.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Omni Cable, LLC — free Get an email when a new federal OSHA severe-injury report for Omni Cable, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
OMNI CABLE, LLC
Site address
3350 LISBON STREET
City
AURORA
State
CO
ZIP
80011
Mailing
3350 NORTH LISBON STREET, AURORA, CO 80011
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517911
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 20 exposed
Issued
Jul 11, 2023
Abate by
Jul 17, 2023
Penalty
Initial $3,572 · Current $1,500 Reduced
29 CFR 1910.101(b): Compressed gas cylinders were not stored in accordance with Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b):  (a) On and before 2/7/23, the employer did not ensure that all compressed gas cylinders were properly stored to where they would be secured from sustaining damage, in that one propane cylinder and one unmarked compressed gas cylinder were standing upright unsecured near the door to the overstock yard.  This condition exposed employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3572

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 11, 2023
Abate by
Sep 8, 2023
Penalty
Initial $6,250 · Current $3,500 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from hazards created by ingoing nip points, rotating parts, flying chips and sparks:  (a)	On and before 2/7/23, the employer did not ensure that the Reel-O-Matic material handling equipment model HSS 753, serial # 2-0050-E14, capacity 150 was effectively guarded to protect employees from rotating and other moving parts of the machine while it was in operation.  This condition exposed employees to laceration and amputation hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6250

View Omni Cable, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346485758.