Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEFCO CONSTRUCTION SUPPLY, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEFCO CONSTRUCTION SUPPLY, LLC. in 411 BURNHAM STREET, EAST HARTFORD, CT 06108 (NAICS 423840). OSHA activity number 346489206.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nefco Construction Supply, LLC. — free Get an email when a new federal OSHA severe-injury report for Nefco Construction Supply, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
411 BURNHAM STREET
City
EAST HARTFORD
State
CT
ZIP
06108
Mailing
ATTN: BILL ZERONSA 411 BURNHAM STREET, EAST HARTFORD, CT 06108
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
Employees
222
Ownership type
A

3 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 18, 2023
Penalty
Initial $8,372 · Current $5,860 Reduced
29 CFR  1910.28(b)(1)(i):The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:  Shipping and Receiving, Mezzanine Floor: On or about February 8, 2023, the upper and lower mezzanine opening was being used as access to the mezzanine floor via forklift for shipping and receiving, exposing employees to a fall of approximately 12 feet from the lower mezzanine and approximately 15 feet from the upper mezzanine without fall protection.
Recent events (2)
  • — I (S) $5860.4
  • — Z (S) $8372

1910.305 G01 IV D

Other-than-serious 1 instance 4 exposed
Issued
Apr 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(D): The employer did not ensure that flexible cords were not attached to building surfaces.  Main Shipping area: On or about February 8, 2023, extension cord(s) were attached to electrical conduit using plastic tie-wraps energizing the following equipment:  A. Crown WP Series 3035-45 Electric Pallet Jack
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Apr 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Main shipping area: On or about February 8, 2023, a portable fire extinguisher was not mounted and found on the ground up against the vertical frame making the extinguisher inaccessible and subjecting employees to prolonged fire exposure and the byproducts of combustion.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nefco Construction Supply, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346489206.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.