OSHA Inspection: ALLIED PRECISION FABRICATIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALLIED PRECISION FABRICATIONS, INC. in 1105 FOUNDATION DRIVE, CALDWELL, TX 77836 (NAICS 332999). OSHA activity number 346492283.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allied Precision Fabrications, INC. — free Get an email when a new federal OSHA severe-injury report for Allied Precision Fabrications, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1105 FOUNDATION DRIVE
City
CALDWELL
State
TX
ZIP
77836
Mailing
1105 FOUNDATION DRIVE, CALDWELL, TX 77836
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2023
Abate by
May 31, 2023
Penalty
Initial $4,465 · Current $2,200 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded or guards were not designed and constructed to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s).  On or about January 19, 2023, and at times prior thereto, an employee was utilizing operating the Di-Acro, hydra-power press brake model # 75-10 to bend hinges that did not have a guard at the point of operation, exposing the employee to a pinch-point hazard.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4465

1910.243 C01 II A

Serious Gravity 1 1 instance 2 exposed
Issued
May 4, 2023
Abate by
May 31, 2023
Penalty
Initial $2,678 · Current $1,300 Reduced
29 CFR  1910.243(c)(1)(ii)(a): Portable abrasive wheels were not equipped with guards to cover the spindle end, nut and outer flange:  On or about February 8, 2023, and at times prior thereto, two employees were performing grinding/sanding operations with pneumatic handheld tools that were not equipped with a guard, exposing the employees to a struck-by hazard.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2678

1910.304 G05

Serious Gravity 5 1 instance 2 exposed
Issued
May 4, 2023
Abate by
May 31, 2023
Penalty
Initial $3,572 · Current $1,750 Reduced
29 CFR  1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.  On or about January 19, 2023, and at times prior thereto, two employees were using a Lasko pedestal fan model # NSC-43 to control dust and cool off the work area that was missing the grounding pin, exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3572

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2023
Abate by
May 31, 2023
Penalty
Initial $3,572 · Current $1,750 Reduced
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service.  On or about January 19, 2023, and at times prior thereto, an employee was using the Di-Acro hydra-power press brake model # 75-10 to bend hinges that had outer sheathing missing from the power cord and the extension cord in which the power cord was plugged into, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3572

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2023
Abate by
May 31, 2023
Penalty
Initial $3,572 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  On or about January 19, 2023, and at times  prior thereto, an employee was using the Di-Acro hydra-power press brake model # 75-10 to bend hinges that had a power cord and extension cord being used as a substitute for the fixed wiring of a structure, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3572