CALDWELL, TX —
OSHA Inspection: ALLIED PRECISION FABRICATIONS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALLIED PRECISION FABRICATIONS, INC. in 1105 FOUNDATION DRIVE, CALDWELL, TX 77836 (NAICS 332999). OSHA activity number 346492283.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLIED PRECISION FABRICATIONS, INC.
- Site address
- 1105 FOUNDATION DRIVE
- City
- CALDWELL
- State
- TX
- ZIP
- 77836
- Mailing
- 1105 FOUNDATION DRIVE, CALDWELL, TX 77836
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A03 II
- Issued
- May 4, 2023
- Abate by
- May 31, 2023
- Penalty
- Initial $4,465 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded or guards were not designed and constructed to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). On or about January 19, 2023, and at times prior thereto, an employee was utilizing operating the Di-Acro, hydra-power press brake model # 75-10 to bend hinges that did not have a guard at the point of operation, exposing the employee to a pinch-point hazard.
Recent events (2)
- — I (S) $2200
- — Z (S) $4465
1910.243 C01 II A
- Issued
- May 4, 2023
- Abate by
- May 31, 2023
- Penalty
- Initial $2,678 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): Portable abrasive wheels were not equipped with guards to cover the spindle end, nut and outer flange: On or about February 8, 2023, and at times prior thereto, two employees were performing grinding/sanding operations with pneumatic handheld tools that were not equipped with a guard, exposing the employees to a struck-by hazard.
Recent events (2)
- — I (S) $1300
- — Z (S) $2678
1910.304 G05
- Issued
- May 4, 2023
- Abate by
- May 31, 2023
- Penalty
- Initial $3,572 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. On or about January 19, 2023, and at times prior thereto, two employees were using a Lasko pedestal fan model # NSC-43 to control dust and cool off the work area that was missing the grounding pin, exposing the employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1750
- — Z (S) $3572
1910.334 A02 II
- Issued
- May 4, 2023
- Abate by
- May 31, 2023
- Penalty
- Initial $3,572 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service. On or about January 19, 2023, and at times prior thereto, an employee was using the Di-Acro hydra-power press brake model # 75-10 to bend hinges that had outer sheathing missing from the power cord and the extension cord in which the power cord was plugged into, exposing the employee to an electrical shock hazard.
Recent events (2)
- — I (S) $1750
- — Z (S) $3572
1910.305 G01 IV A
- Issued
- May 4, 2023
- Abate by
- May 31, 2023
- Penalty
- Initial $3,572 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. On or about January 19, 2023, and at times prior thereto, an employee was using the Di-Acro hydra-power press brake model # 75-10 to bend hinges that had a power cord and extension cord being used as a substitute for the fixed wiring of a structure, exposing the employee to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3572
More inspections at Allied Precision Fabrications, INC.
View Allied Precision Fabrications, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346492283.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.