COMMERCE CITY, CO —
OSHA Inspection: JM CONVEYOR SERVICES INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JM CONVEYOR SERVICES INC. in 7905 INTERSTATE 76 FRONTAGE ROAD, COMMERCE CITY, CO 80022 (NAICS 333922). OSHA activity number 346503014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JM CONVEYOR SERVICES INC.
- Site address
- 7905 INTERSTATE 76 FRONTAGE ROAD
- City
- COMMERCE CITY
- State
- CO
- ZIP
- 80022
- Mailing
- 7905 INTERSTATE 76 FRONTAGE ROAD, HENDERSON, CO 80640
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333922
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.94 C04 I
- Issued
- Jul 28, 2023
- Abate by
- Sep 14, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1910.94(c)(4)(i): 29 CFR 1910.94(c)(4)(i): Spray rooms, including floors, shall be constructed of masonry, concrete, or other noncombustible material. (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022; On or about February 14, 2023, and at times prior, the employer exposed employees to combustible chemicals when they allowed spray finishing with combustible materials, such as toluene and Anchor Industrial LoVOC Industrial Enamel, in a spray room with floors constructed of dirt. The employer did not provide a spray room, including floors, that was constructed of masonry, concrete, or other noncombustible material as required in 1910.94(c)(4)(i).
Recent events (1)
- — Z (S) $4688
1910.94 C06 I
- Issued
- Jul 28, 2023
- Abate by
- Sep 14, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.94(c)(6)(i): The velocity of air into all openings of a spray booth was less than that specified in Table G-10 for the operating conditions specified: (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022; On or about February 14, 2023, and at times prior, the employer exposed employees to respiratory hazards when only two exhaust fans running at 3200 CFM for a 43,956 ft2 building were used as ventilation for the spray finishing room where employees spray toluene and Anchor Industrial LoVOC Industrial Enamel. Spray rooms were not adequately ventilated so that the atmosphere in the breathing zone of the operator was maintained in accordance with the requirements of paragraph (c)(6)(ii) of this section of 1910.94(c)(4).
Recent events (1)
- — Z (S) $0
1910.106 E02 II B
- Issued
- Jul 28, 2023
- Abate by
- Aug 23, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons of Category 2, 3, or 4 flammable liquids in containers: (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at times prior, employees were exposed to combustion hazards when 53 5 gallon containers of Anchor Industrial LoVOC Industrial Enamel (Category 3 Combustible) was stored inside inside the spray finishing room. The quantity of liquid stored was 265 gallons.
Recent events (1)
- — Z (S) $4688
1910.134 C01
- Issued
- Jul 28, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022 : On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer required respirators but did not implement a written respiratory protection program describing necessary elements of respiratory protection. (b) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022 : On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer did not provide medical evaluations to employees required to use the respirators as required in 1910.134(c)(1)(ii). (c) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022 : On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer did not provide fit testing procedures for tight-fitting respirators to employees required to use the respirators as required in 1910.134(c)(1)(iii). (d) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer did not provide procedures for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators of employees required to use the respirators as required in 1910.134(c)(1)(v). (e) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer did not provide training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations for employees required to use the respirators as required in 1910.134(c)(1)(vii). (f) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022 : On or about February 14, 2023, and at times prior, employees were exposed to primary metals through welding fumes and chemical vapors from paint spraying at unknown levels while performing their daily work duties. The employer did not establish work-site specific procedures to regularly evaluate the effectiveness of the program as required in 1910.134(c)(1)(ix).
Recent events (1)
- — Z (S) $4688
1910.134 D01 III
- Issued
- Jul 28, 2023
- Abate by
- Aug 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii):The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at time prior, employees were exposed to respiratory hazards when the employer did not determine a reasonable estimate of employee exposure to primary metals from welding operations and/or various chemical hazards, including but not limited to toluene exposure , from spray finishing before selecting the the required respiratory protection.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Jul 28, 2023
- Penalty
- Initial $2,009 · Current $2,009
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii) (a) J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at times prior, the employer had not implemented a written hazard communication program to include information associated with hazards from exposure to primary metals, chemicals from spray finishing, and abrasive blast materials (b)J & M Conveyor, 7905 Interstate 76 Frontage Road, Commerce City, CO 80022: On or about February 14, 2023, and at times prior, the employer did not make the written hazard communication program available upon request to the employees or their designated representatives as required in 1910.1200(e)(4).
Recent events (1)
- — Z (S) $2009
More inspections at JM Conveyor Services INC.
View JM Conveyor Services INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333922)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346503014.