OSHA Inspection: JAMES HARDIE BUILDING PRODUCTS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JAMES HARDIE BUILDING PRODUCTS INC. in 17 UNYTITE DR., LA SALLE, IL 61301 (NAICS 423320). OSHA activity number 346505332.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch James Hardie Building Products INC. — free Get an email when a new federal OSHA severe-injury report for James Hardie Building Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
17 UNYTITE DR.
City
LA SALLE
State
IL
ZIP
61301
Mailing
17 UNYTITE DR., PERU, IL 61354
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
415
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 9, 2023
Abate by
Jul 11, 2023
Penalty
Initial $15,625 · Current $9,375 Reduced
29 CFR  1910.147(d): Application of control. The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6).  On or about February 6, 2023, the employer did not ensure that employees implemented energy control application steps prior to allowing them to paint motor covers at the Trim CP4 Laminator Outfeed Roll Case line. The motors were not shut down or turned off prior to employees engaging in this servicing and maintenance activity, exposing them to pinch/nip point hazards and amputation injuries.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625