Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LETSOS COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LETSOS COMPANY in 23623 COLONIAL PAKWAY, KATY, TX 77493 (NAICS 452319). OSHA activity number 346505605.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Letsos Company — free Get an email when a new federal OSHA severe-injury report for Letsos Company is published. One employer, no account, unsubscribe in one click.
Establishment
LETSOS COMPANY
Site address
23623 COLONIAL PAKWAY
City
KATY
State
TX
ZIP
77493
Mailing
8435 WESTGLEN DRIVE, HOUSTON, TX 77063
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452319
Employees
13
Ownership type
A

5 citations on file for this inspection.

1910.119 F04

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel:  a) On February 11, 2023, and at times prior, at the 99 Cents Katy facility, the employer did not implement safe work practices such as but not limited to the positive isolation of material and safe line opening procedures before cutting through a 4" pipe. This condition exposed employees to the toxic hazards of ammonia.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.147 C04 I

Deleted Serious Gravity 10 50 instances 3 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On February 11, 2023, and at times prior, at the 99 Cents Katy facility, the employer did not utilize an energy control procedure before employees opened a refrigeration piping system, exposing employees to the toxic hazards of ammonia.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.119 H03 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.119(h)(3)(ii): The contract employer did not assure that each contract employee was instructed in the known fire, explosion, or toxic release hazards related to his/her job and the process, and the applicable provisions of the emergency action plan:  a) On February 11, 2023, and at times prior, at the 99 Cents Katy facility, the contract employer did not assure that a contract employee was instructed in the applicable provisions of the emergency action plan. This condition exposed the employee to toxic hazards in the event of an ammonia release.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.120 Q01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR  1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to the commencement of emergency response operations:  (a) On February 11, 2023, and at times prior, at the 99 Cents Katy facility, the employer did not develop and implement an emergency response plan before the commencement of emergency response operations. This condition exposed employees to toxic hazards during the release of ammonia.
Recent events (3)
  • — F (S) $15625
  • — C (S) $15625
  • — Z (S) $15625

1910.134 F02

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $15,625 · Current $9,375 Reduced
29 CFR  1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:   a) On February 11, 2023, and at times prior, at the 99 Cents, Katy facility, an employee who wore a tight-fitting respirator in response to an ammonia release was not fit-tested annually. This condition exposed the employee to toxic hazards during the ammonia release.
Recent events (3)
  • — F (O) $9375
  • — C (S) $15625
  • — Z (S) $15625

View Letsos Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346505605.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.