CALDWELL, ID —
OSHA Inspection: JOHNSON THERMAL SYSTEMS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JOHNSON THERMAL SYSTEMS, INC. in 1711 SLIPSTREAM WAY, CALDWELL, ID 83605 (NAICS 423740). OSHA activity number 346508948.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNSON THERMAL SYSTEMS, INC.
- Site address
- 1711 SLIPSTREAM WAY
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 1711 SLIPSTREAM WAY, CALDWELL, ID 83605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423740
- Employees
- 260
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 12, 2023
- Penalty
- Initial $7,590 · Current $7,590
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the struck-by or crushing hazards when operating a forklift without the use of a restraint device: (a) On or about February 15, 2023, and at time prior to, the employer did not enforce the use of a seatbelt for the employee operating the Toyota side shifter, S/N: 11753 in the yard area. (b) Inside bay: On or about February 15, 2023, and at time prior to, the employer did not enforce the use of a seatbelt for employee operating the Hyster, model H50CT, S/N: A274V03637M to move equipment, such as but not limited to, the welding machines used for fabrication. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $7590
- — Z (S) $7590
1910.178 A04
- Issued
- Jul 12, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4):Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval (a) On or about February 15, 2023, and at time prior to, the Crown ecologic powered industrial truck, 65F-SSS-B060; serial number 9A197675 had holes drilled in to the forks in order to use an attachment to move large I-beams of steel. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 A05
- Issued
- Jul 12, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5):The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: (a) On or about February 15, 2023, and at time prior to, the Crown ecologic powered industrial truck, 65F-SSS-B060; serial number 9A197675 used an attachment to move large I-beams of steel that had not been evaluated for capacity or load. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Jul 12, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Yard and Fabrication Areas: On or about February 15, 2023, and at time prior to, the employer had not ensured that all employees that are operating powered industrial trucks were certified and evaluated prior to driving the forklifts. NOTE: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.135 A01
- Issued
- Jul 12, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $7,590 · Current $7,590
General-duty citation text
29 CFR 1910.135(a)(1):The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: (a) Throughout fabrication areas: On or about February 15, 2023 and at times prior to, employees working on and under scaffolds and cranes were not wearing hard hats when overhead work was being done. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $7590
- — Z (S) $7590
1910.242 B
- Issued
- Jul 12, 2023
- Abate by
- Jul 24, 2023
- Penalty
- Initial $5,692 · Current $5,692
General-duty citation text
29 CFR 1910.242(b):Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes: (a) On February 15, 2023; compress air used for cleaning measured 107 PSI when dead ending occurred.
Recent events (2)
- — I (O) $5692
- — Z (S) $5692
1910.305 G02 III
- Issued
- Jul 12, 2023
- Penalty
- Initial $5,692 · Current $5,692
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a)On or about February 15, 2023 and at times prior to, two extension cords used to provide power to the two welding machines were damaged in that they had separated from the cord plug. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $5692
- — Z (S) $5692
1910.134 C02 I
- Issued
- Jul 12, 2023
- Abate by
- Aug 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that voluntary respirator use was permissible: (a) On or about February 15, 2023, and at time prior to, the employer had not provided information regarding the proper use and limitations of employees wearing filtering facepiece (N-95) respirators for comfort while performing welding and grinding activities. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Johnson Thermal Systems, INC.
View Johnson Thermal Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423740)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346508948.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.