Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LARSON FIRE PROTECTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LARSON FIRE PROTECTION, LLC in 901 N 27TH STREET, BOISE, ID 83702 (NAICS 238220). OSHA activity number 346521396.

Watch Larson Fire Protection, LLC — free Get an email when a new federal OSHA severe-injury report for Larson Fire Protection, LLC is published. One employer, no account, unsubscribe in one click.
Site address
901 N 27TH STREET
City
BOISE
State
ID
ZIP
83702
Mailing
P.O. BOX 2030, EAGLE, ID 83616
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $2250.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to the work environment to control or eliminate any hazards or other exposure to illness or injury:  a) Jobsite: On February 22, 2023, an employee installing a fire protection water line, worked in a 5.7-foot-deep area of a trench without any cave-in protective measures used. The employee and the responsible person on site did not recognize the hazard or take action to correct or minimize the hazard.   Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3349

1926.651 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:  a) a) Jobsite: On February 22, 2023, an inspection by a competent person had not been conducted prior to allowing an employee to enter a 5.7-foot-deep area of a trench to make adjustments to a fire protection water line.  Cave in protection was not used.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $2250.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  a) Jobsite: On February 22, 2023, an employee worked in a 5.7-foot-deep area of a trench to assist in fire protection water line installation.  Cave-in protection was not used.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3349