GENOA, IL —
OSHA Inspection: EM CUSTOM HOMES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EM CUSTOM HOMES, INC. in 1005 PERSIMMON DR., GENOA, IL 60135 (NAICS 238130). OSHA activity number 346526189.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EM CUSTOM HOMES, INC.
- Site address
- 1005 PERSIMMON DR.
- City
- GENOA
- State
- IL
- ZIP
- 60135
- Mailing
- 75 N ANDERSON, AURORA, IL 60505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 D01
- Issued
- Jul 6, 2023
- Abate by
- Aug 24, 2023
- Penalty
- Initial $376 · Current $376
General-duty citation text
29 CFR 1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. EM CUSTOM HOMES, INC. failed to submit documents to OSHA within 10 calendar days after the abatement date verifying that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 05/19/2023 01 02 05/19/2023 02 01 05/19/2023 Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (O) $376
1926.501 B13
- Issued
- Apr 21, 2023
- Abate by
- May 19, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about February 21, 2023 the employer did not ensure that employees engaged in residential construction activities were protected from fall hazards. Employees installing roof sheathing were not utilizing fall protection, exposing them to falls of approximately 12 feet to the ground below. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (1)
- — Z (S) $4688
1926.1053 B01
- Issued
- Apr 21, 2023
- Abate by
- May 19, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. On or about February 21, 2023 employees used an extension ladder that did not extend three feet past the point of access, exposing the employee to falls of approximately 12 feet. Employees were exposed as they accessed the roof area of new construction dwelling to install sheathing. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (1)
- — Z (S) $3349
1926.503 B01
- Issued
- Apr 21, 2023
- Abate by
- May 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1):The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. On or about February 21, 2023 the employer failed to certify that employees had been trained to recognize and minimize fall hazards. Employees were exposed to fall hazards in excess of 12 feet while performing roof sheathing activities on a new residential structure without using fall protection. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)
Recent events (1)
- — Z (O) $0
More inspections at EM Custom Homes, INC.
View EM Custom Homes, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346526189.