MONTGOMERY, AL —
OSHA Inspection: RHEEM MANUFACTURING COMPANY, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RHEEM MANUFACTURING COMPANY, INC in 2600 GUNTER PARK DRIVE EAST, MONTGOMERY, AL 36109 (NAICS 339999). OSHA activity number 346533474.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RHEEM MANUFACTURING COMPANY, INC
- Site address
- 2600 GUNTER PARK DRIVE EAST
- City
- MONTGOMERY
- State
- AL
- ZIP
- 36109
- Mailing
- 2600 GUNTER PARK DRIVE EAST, MONTGOMERY, AL 36109
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 620
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.255 B04
- Issued
- Apr 7, 2023
- Penalty
- Initial $13,281 · Current $13,281
General-duty citation text
29 CFR 1910.255(b)(4): All press welding machine operations, where there is a possibility of the operator's fingers being under the point of operation, were not effectively guarded by the use of a device such as an electronic eye safety circuit, two hand controls or protection similar to that prescribed for punch press operation. a) Coupling to Shell Assembly line, Projection Welder 5151; On or about February 17, 2023 and times prior the employer exposed employees to amputation hazards in that the employer failed to ensure the projection welder machine was effectively guarded against employees being able to access the point of operation.
Recent events (2)
- — I (S) $13281
- — Z (S) $13281
1910.255 B05
- Issued
- Apr 7, 2023
- Abate by
- Apr 19, 2023
- Penalty
- Initial $9,488 · Current $0 Reduced
General-duty citation text
29 CFR 1910.255(b)(5): The hazard of flying sparks was not, wherever practical, eliminated by installing a shield guard of safety glass or suitable fire resistant plastic at the point of operation: a) Coupling to Shell Assembly line, Projection Welder 5151; On or about February 17, 2023 and times prior the employer exposed employees to burn hazards in that the employer did not provide guarding which eliminated the hazard of flying sparks for employees performing welding activities on a coupling to shell projection welder.
Recent events (2)
- — I (S) $0
- — Z (S) $9488
More inspections at Rheem Manufacturing Company, INC
View Rheem Manufacturing Company, INC's full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346533474.