Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: LAUREN R.M. SIDING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LAUREN R.M. SIDING LLC in 7294 CUTLER DRIVE, LOT# 6587, POWELL, OH 43065 (NAICS 238170). OSHA activity number 346535446.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lauren R.M. Siding LLC for free Get an email when a new federal OSHA severe-injury report for Lauren R.M. Siding LLC is published. One employer, no account, unsubscribe in one click.
Site address
7294 CUTLER DRIVE, LOT# 6587
City
POWELL
State
OH
ZIP
43065
Mailing
4488 COLLINGDALE ROAD, COLUMBUS, OH 43231
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1926.451 C02 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 12, 2023
Abate by
May 24, 2023
Penalty
Initial $3,349 · Current $0 Reduced
29 CFR  1926.451(c)(2)(i):  Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.  a. Located at 7254 Cutler Drive, Lot 6587, Powell Ohio:   On or about March 01, 2023, the employer did not ensure that footing for the pump jack scaffold that was erected on the porch rooftop was level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3349

1926.451 G02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
May 12, 2023
Abate by
May 24, 2023
Penalty
Initial $4,688 · Current $0 Reduced
29 CFR  1926.451(g)(2):  Effective September 2, 1997, the employer shall have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Employers are required to provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection is feasible and does not create a greater hazard.  a. Located at 7254 Cutler Drive, Lot 6587, Powell Ohio:   On or about March 01, 2023, the employer did not have a competent person onsite to determine the safety and feasibility for fall protection when employees erected the pump jack scaffold system. The employees were thereby exposed to a fall hazard of 10 feet 10 inches to the ground level.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4688

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
May 12, 2023
Abate by
May 24, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR  1926.501(b)(13):  "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. Located at 7254 Cutler Drive, Lot 6587, Powell Ohio:   On or about March 01, 2023, the employer did not ensure that employees were protected from falling when they installed roof flashing from elevated working surface of the steep 6 on 12 pitch rooftop.  The employees were thereby exposed to a fall hazard of 10 feet 10 inches to the ground level.
Recent events (2)
  • · I (S) $2812.8
  • · Z (S) $4688

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
May 12, 2023
Abate by
May 24, 2023
Penalty
Initial $3,349 · Current $0 Reduced
29 CFR  1926.503(a)(1):  The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a.  Located at 7254 Cutler Drive, Lot 6587, Powell Ohio:   On or about March 01, 2023, the employer did not provide a training program to enable each employee to recognize and minimize fall hazards when they had the potential to be exposed.  Two employees installed roof flashing from elevated working surface off the steep 6 on 12 pitch rooftop and were thereby exposed to a fall hazard of 10 feet 10 inches to the ground level.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3349

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 346535446.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.